Section 6 - Storage
90-864197072 NOVEMBER 2007
Page 79
5. Pull lever on air pump (vertical) to lock pump on the fitting.
8293
b
d
e
a
c
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve
d -
Air pump
e -
Lever (locking)
6. Pump air into the system until both green indicators extend and water drains from both
sides of the engine. The port side will begin draining before the starboard side.
7. Immediately remove the blue drain plug from the side of the thermostat housing or the
heat exchanger. This must be removed within 30 seconds to properly vent the cooling
system.
6124
a
b
c
d
6125
a
b
c
d
Closed Cooled Models
Seawater Cooled Models
a -
Blue drain plug location
b -
Blue air pump
c -
Air manifold
d -
Green indicators
Содержание 6.2 MPI
Страница 8: ...Page iv 90 864197072 NOVEMBER 2007 ...
Страница 20: ...Section 1 Warranty Notes Page 12 90 864197072 NOVEMBER 2007 ...
Страница 36: ...Section 2 Getting to Know Your Power Package Notes Page 28 90 864197072 NOVEMBER 2007 ...
Страница 56: ...Section 4 Specifications Notes Page 48 90 864197072 NOVEMBER 2007 ...
Страница 100: ...Section 6 Storage Notes Page 92 90 864197072 NOVEMBER 2007 ...
Страница 106: ...Section 7 Troubleshooting Notes Page 98 90 864197072 NOVEMBER 2007 ...