background image

INSTALLATION INSTRUCTIONS 

10 

Rev 2.0

 

Mercator Pty Ltd. All Rights Reserved. 

 

 

 

 

 

 

11.

 

Reconnect  lamp  wire  and  re-install  fascia  to  main 

unit,  ensuring  fascia  has  clicked  into  place  and  is 
secure. 

 
Before first use, turn on heat lamp and exhaust fan for 

at least 5 minutes to eliminate any lingering odour. 

 

 

Содержание BH151ESWSL

Страница 1: ...t which is contained within this package THE QUALITY BRAND IN FANS INSTALLATION AND OPERATION INSTRUCTION BOOK REV 2 0 DOMINO SERIES MODELS BH151ESWWH BH151ESWSL BATHROOM HEATER WITH EXHAUST FAN AND L...

Страница 2: ...Rev 2 0 Mercator Pty Ltd All Rights Reserved INTRODUCTION SPECIFICATIONS 1 SAFETY PRECAUTIONS 2 UNPACKING YOUR HEATER 3 CHOOSING A PROPER LOCATION 4 INSTALLATION INSTRUCTIONS 6 WIRING DIAGRAM 11 CARE...

Страница 3: ...ARNING CAUTION notice until the indicated conditions are fully understood and met SAFETY SYMBOLS Alternating current Protective earth Warning Caution PRODUCT SPECIFICATIONS MODEL OPERATING VOLTAGE OPE...

Страница 4: ...trols CANNOT be touched by a person in the bath or shower 9 Do not install the product directly above shower cubicle or bath enclosure or a location where water will splash onto it 10 Do not install t...

Страница 5: ...ng material as it may be needed if warranty replacement or repair is ever necessary 1 x bathroom heater with 2 x 10W LED panels 1 x 800W linear heat lamp 1 x 1 5m 150mm flexible duct 1 x 3 gang switch...

Страница 6: ...ct must be horizontally mounted on a ceiling and not on a wall or a raked ceiling 4 It is recommended that the air outlet points towards an outer wall and the ductworks interconnecting the air outlet...

Страница 7: ...d ensuring ducting is as short as possible 2 Ensure ducting is fully extended properly supported straight and not slacking 3 Ensure ducting is not obstructed or squeezed 4 Avoid bending the duct 5 Do...

Страница 8: ...location must be clear of obstacles such as cables utility pipes and joists INSTALLING GRILLE ON WALL 2 Mark out a circle of the base diameter at desired location Using an appropriate cutting device...

Страница 9: ...to the ceiling Tips Do not cut the hole any larger than the specified cut out dimension 6 Remove fascia from the main unit with care by pressing the two spring levers attached to rear of fascia and d...

Страница 10: ...ring installation Connect ducting to outlet and secure its connection Insert heater into cut out hole at an angle ensuring duct connection is intact and no cable or insulating material rest over or ag...

Страница 11: ...ION INSTRUCTIONS 9 Rev 2 0 Mercator Pty Ltd All Rights Reserved 10 Ensure the unit is held securely in place by the pushing side clips outwards and tighten the screws until main unit rests flush to th...

Страница 12: ...Pty Ltd All Rights Reserved 11 Reconnect lamp wire and re install fascia to main unit ensuring fascia has clicked into place and is secure Before first use turn on heat lamp and exhaust fan for at lea...

Страница 13: ...designed to be connected with the product supplied in this package only Other uses may cause personal injury or fire hazard Make sure electricity is turned off at the main power box before commencing...

Страница 14: ...h a clean cloth dampened with petroleum free detergent or liquid glass cleaner 2 Do not use alcohol cleaner or thinner or liquid that is corrosive to plastic for cleaning 3 Dry the product completely...

Страница 15: ...an be replaced when operation lifetime of LED lamp is reached 1 The following fascia is recommended for replacement Mercator Model no XBH1511WH Domino fascia White Mercator Model no XBH1511SL Domino f...

Отзывы: