INSTALLATION INSTRUCTIONS 

Rev 2.0

 

Mercator Pty Ltd. All Rights Reserved. 

 

 

 

Make  sure  electricity  is  turned  off  at  the  main  power  box  before  commencing  work.  Turn  off  the 
power by removing fuse or turning off circuit breaker before installing the product and replacing 

lamp. 

 

Make sure that ceiling joists are strong enough and of adequate size to support the weight of  at 
least 35 kg. 

 

1.

 

Take some time choosing an appropriate mounting 

location and direction with reference to instructions in 
previous page. Make sure all clearances required around 

the product are observed and there is no obstructing 
structure nearby the outlet. The area behind the 

intended location must be clear of obstacles such as 
cables, utility pipes and joists. 

 

 

INSTALLING GRILLE ON WALL 

 

 

2.

 

Mark  out  a  circle  of  the  base  diameter  at  desired 

location.  Using  an  appropriate  cutting  device,  cut  along 
the  line  and  remove  excess  material  from  the  marked 

location. 

 

 

 

3.

 

Remove  louver  from  the  base  of  grille  noting  there  are 

four  screw  holes  on  the  base.  Push  a  duct  through  the 
hole and connect it to the collar of the base. Secure the 

ducting  connection  with  the  clamp  provided.  Then  fix 

the  base  at  the  desired  spot  using  four  suitable  screws 
(not  provided).  Install  louver  onto  the  base.  Install 

ductwork  following  recommendation  on  ducting 
installation in previous page, and direct the duct towards 

general direction of cut out and air outlet on the product. 
 

 

 

INSTALLING BATHROOM HEATER 

 

 

4.

 

Use a pencil and trace around the template supplied the 
package.  

Содержание BH151ESWSL

Страница 1: ...t which is contained within this package THE QUALITY BRAND IN FANS INSTALLATION AND OPERATION INSTRUCTION BOOK REV 2 0 DOMINO SERIES MODELS BH151ESWWH BH151ESWSL BATHROOM HEATER WITH EXHAUST FAN AND L...

Страница 2: ...Rev 2 0 Mercator Pty Ltd All Rights Reserved INTRODUCTION SPECIFICATIONS 1 SAFETY PRECAUTIONS 2 UNPACKING YOUR HEATER 3 CHOOSING A PROPER LOCATION 4 INSTALLATION INSTRUCTIONS 6 WIRING DIAGRAM 11 CARE...

Страница 3: ...ARNING CAUTION notice until the indicated conditions are fully understood and met SAFETY SYMBOLS Alternating current Protective earth Warning Caution PRODUCT SPECIFICATIONS MODEL OPERATING VOLTAGE OPE...

Страница 4: ...trols CANNOT be touched by a person in the bath or shower 9 Do not install the product directly above shower cubicle or bath enclosure or a location where water will splash onto it 10 Do not install t...

Страница 5: ...ng material as it may be needed if warranty replacement or repair is ever necessary 1 x bathroom heater with 2 x 10W LED panels 1 x 800W linear heat lamp 1 x 1 5m 150mm flexible duct 1 x 3 gang switch...

Страница 6: ...ct must be horizontally mounted on a ceiling and not on a wall or a raked ceiling 4 It is recommended that the air outlet points towards an outer wall and the ductworks interconnecting the air outlet...

Страница 7: ...d ensuring ducting is as short as possible 2 Ensure ducting is fully extended properly supported straight and not slacking 3 Ensure ducting is not obstructed or squeezed 4 Avoid bending the duct 5 Do...

Страница 8: ...location must be clear of obstacles such as cables utility pipes and joists INSTALLING GRILLE ON WALL 2 Mark out a circle of the base diameter at desired location Using an appropriate cutting device...

Страница 9: ...to the ceiling Tips Do not cut the hole any larger than the specified cut out dimension 6 Remove fascia from the main unit with care by pressing the two spring levers attached to rear of fascia and d...

Страница 10: ...ring installation Connect ducting to outlet and secure its connection Insert heater into cut out hole at an angle ensuring duct connection is intact and no cable or insulating material rest over or ag...

Страница 11: ...ION INSTRUCTIONS 9 Rev 2 0 Mercator Pty Ltd All Rights Reserved 10 Ensure the unit is held securely in place by the pushing side clips outwards and tighten the screws until main unit rests flush to th...

Страница 12: ...Pty Ltd All Rights Reserved 11 Reconnect lamp wire and re install fascia to main unit ensuring fascia has clicked into place and is secure Before first use turn on heat lamp and exhaust fan for at lea...

Страница 13: ...designed to be connected with the product supplied in this package only Other uses may cause personal injury or fire hazard Make sure electricity is turned off at the main power box before commencing...

Страница 14: ...h a clean cloth dampened with petroleum free detergent or liquid glass cleaner 2 Do not use alcohol cleaner or thinner or liquid that is corrosive to plastic for cleaning 3 Dry the product completely...

Страница 15: ...an be replaced when operation lifetime of LED lamp is reached 1 The following fascia is recommended for replacement Mercator Model no XBH1511WH Domino fascia White Mercator Model no XBH1511SL Domino f...

Отзывы: