Using a damaged device

 

Do not use a damaged device.

 

Only have a qualified electrician repair the device.

Manipulation of the device

 

Do not make changes or modifications to the device.

 

Do not remove any parts of the device.

Use as a climbing aid

 

Do not sit on the power distribution box or use it as a 

climbing aid.

Use of unsuitable cleaning agents

 

Do not use aggressive cleaning agents or chemicals for 

cleaning because these may adversely affect and dama-

ge surfaces.

Use of unauthorised spare parts and accessories

 

Use only spare parts and accessories that are manufactu-

red and / or approved by MENNEKES.

Use under unsuitable ambient conditions

 

Do not use the power distribution box in potentially-

explosive atmospheres, where flammable liquids, gases 

or dust are present – risk of fire and explosion!

Connected power tools generate sparks that can ignite 

dust or fumes.

2.3 Intended 

use

The power distribution box is used solely for the distribution 

and control of electrical energy.

The power distribution box is intended for use in indoor and 

outdoor locations as a portable power distribution system.

The power distribution box is not intended for use 

as a stationary device (e. g. wall-mounted device) 

and must not be used as such.

The user is responsible for ensuring compliance with the 

intended use of the device and its safe operation.

MENNEKES Elektrotechnik GmbH & Co. KG accepts no lia-

bility for any consequences arising from improper use of the 

device.

Read this operating manual carefully before using the 

power distribution box and fully comply with all of the 

information given therein.

Keep this operating manual available at the device, and 

pass it on to the new user should the device change hands.

2.4 Improper 

use

Using the device is safe only when it is

used as intended.

The following uses are not permitted:

Disregard of the manual

 

Read the manual before using the device.

 

Comply with the described procedure and sequence of 

work steps.

 

Carry out only those tasks you are authorised to per-

form.

Содержание Portable Power Distribution Box

Страница 1: ...ENGLISH 16A 32A 63A 125A Portable Power Distribution Box Operating Manual...

Страница 2: ...2016 MENNEKES Elektrotechnik GmbH Co KG All rights are reserved by the publisher including the reprinting and the duplication of this manual and its translation in whole or in part No part of this man...

Страница 3: ...nto service 13 6 1 1 Connecting the power distribution box 14 6 1 2 Connecting electrical consumers 14 7 Operation 14 7 1 Opening Closing of inspection window 14 7 2 Connecting Removing electrical con...

Страница 4: ...also include further documentation e g instructions for device components diagrams etc which must also be fully observed 1 1 Contact details MENNEKES Elektrotechnik GmbH Co KG Industrial plugs and soc...

Страница 5: ...persons or animals cannot access the device This also includes children and people with disabi lities who are not able to accurately assess the potential hazards associated with handling the device Y...

Страница 6: ...ice Keep animals away from the device Protective measures must be taken as needed Persons under the influence of drugs alcohol or other intoxicating substances must not use the device This can result...

Страница 7: ...ribution box is used solely for the distribution and control of electrical energy The power distribution box is intended for use in indoor and outdoor locations as a portable power distribution system...

Страница 8: ...with hinged lids 5 Nameplate 6 Sign 7 Inspection window 8 Protective elements 9 Front panel The illustrations in this manual may not exactly correspond in a visual sense to the device due to device v...

Страница 9: ...sport of power distribution box CAUTION There is a risk of injury if the device falls Transport the power distribution box with the aid of a second person if needed or use appropriate means of transpo...

Страница 10: ...o tection classes can result in leakage Only connect plugs and sockets with the same protec tion class ATTENTION The use of plugs and sockets with different protection classes will reduce the effect o...

Страница 11: ...ow etc Clean soiled components especially contact parts If there are scorch marks on contact parts e g welding beads have a qualified electrician replace the affected plugs and sockets Only put fault...

Страница 12: ...electric shock A residual current device FI RCD of type AC A of a given electrical installation can in the event of a fault become inoperative due to an impermissible switching sequence if this device...

Страница 13: ...0 6 Setting up process 6 1 Putting the power distribution box into service Prior to putting the power distribution box into service check whether the connection data of the power distributi on box mat...

Страница 14: ...ctrical consu mers Risk of injury Always use the ON OFF switches of electrical consu mers to switch these off before connecting these to the power distribution box Connecting consumers Chapter 7 2 7 O...

Страница 15: ...Cleaning The power distribution box can be cleaned with a dry or a damp cloth However cleaning with a dry cloth at regular intervals is recommended in order to prevent persistent soiling on the surfa...

Страница 16: ...f the supply line Close all protective devices e g inspection window hinged lids for sockets Only clean the power distribution box from the outside ATTENTION Material damage of the device due to incor...

Страница 17: ...material alterations missing com ponents etc and its proper functioning e g protective elements regularly If defects are detected on the device they must be rectified without delay A damaged faulty de...

Страница 18: ...defects are detected on the device they must be rectified before use by a qualified electrician Checking residual current devices FI RCDs Residual current devices FI RCDs can vary in terms of appeara...

Страница 19: ...llations equipped with AC DC sensitive residual current devices FI RCDs of type B B these could sustain damage due to incorrectly performed tests ATTENTION Material damage of protective element due to...

Страница 20: ...rew the screws 1 on the exterior of the enclosure Removing the device carrier Loosen the strain relief of the screwed cable gland of the supply line at the rear of the device Pull the device carrier 1...

Страница 21: ...er Fit the device carrier 1 into the enclosure All the while carefully pulling out the supply line at the rear of the device Once the device carrier is completely seated in the enclo sure fasten the s...

Страница 22: ...mple residual current or an overloaded electrical circuit Situation A A circuit breaker is triggered Course of action Visually inspect the power distribution box and the con nected electrical consumer...

Страница 23: ...ve a positive impact on the service life of the device Clean the device before placing it into storage Chapter 9 Close hinged lids for sockets the inspection window and any other covers Roll up the su...

Страница 24: ...mbH Co KG Industrial plugs and sockets Aloys Mennekes Str 1 57399 Kirchhundem GERMANY Tel 49 0 2723 41 1 Fax 49 0 2723 41 2 14 E Mail info MENNEKES de Internet www MENNEKES de 1010190DS_BAL_Mobiler Ve...

Отзывы: