41 |
P a g e
BLOWER SYSTEM INFORMATION
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
Dual blowers are provided as standard equipment with this FV-41 fireplace. The dual blowers have an air output rating
of 210 CFM (in free air). This fireplace is designed to operate with the blowers turned OFF or ON. Turning the blower
on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this fireplace
is installed in.
BLOWER OPERATION
The remote control system supplied with this appliance can turn the blowers ON or OFF and regulate the speed of the
blowers in six(6) steps.
NOTE: In the Normal Thermostat Mode and the SMART Mode, there will be a time delay in blower operation during
"heat-up" (5 minutes) and extended blower operation during "cool-down" of unit (12-1/2 minutes).
FV-41 BLOWER WIRING DIAGRAM