29
1.
Locate Fiber Coal Bed “A”. This Fiber Coal Bed
installs between the front burner and the front of
the rear burner tube as shown below.
2.
The Fiber Coal Bed “A” is placed directly
behind the front burner. The Coal Bed ‘s front
edge must touch back edge of front burner tube.
3.
Slide Fiber Coal Bed “A” to the left as far as
possible. The left edge of this Coal Bed shall
touch propagation leg of front burner tube.
FIBER COAL BED “A”
A
Left Edge of
Coal Bed “A”
shall touch
right edge of
T- Propagation
tube.
Front Edge of
Coal Bed “A”
shall touch
back edge of
Front Burner
DXV45-DT3 LOG SET INSTALLATION INSTRUCTIONS
LOG “B”
Log “B” installed correctly
7.
MAKE SURE THERE IS NO AIR SPACE
DIRECTLY UNDER THIS LOG.
8.
While pushing log “B” down, put
your fingers behind the top of log
“B” to get a slight angle forward of
about 10 degrees.
4.
Locate Log “B” - Back
right log.
5.
Locate holes on bottom
of log.
6.
Place log “B” onto the 2
pins on right side
behind the rear burner
as shown.
Holes in
bottom of Log
“B”.
B