DXV45 DT4 FEATURES -
QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS
: 40-3/8
” Wide X 39” High X 19-1/8” Deep
MINIMUM FRAMING DIMENSIONS
: 41
” WIDE x 38-1/8” HIGH X 20” DEEP
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 707.5 in
2
. Actual Glass size is 840
in
2
.
MANTEL ALLOWANCE
: 8” Deep Mantel at 14” Above Top Convection Opening
VENT SYSTEM ALLOWANCE
: Top Vent Only. 0
” Vertical 24” max horizontal. 55 feet Vertical Maximum. 5” exhaust and
8
” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ minimum vertical starter
section.
CONTROLS
: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blowers op-
erate on AC Power only.
BLOWER SYSTEM
: 210 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed
Controls or Light Dimmers are allowed in same circuit.
Accent Light System
: Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted
behind lower grill.
BURNER SYSTEM
: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS
: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air
shutter.
LOG SET
: 10-piece, Premium Fiber Log Set with Real- Glow effects and Real ember bed.
REFRACTORY PANELS
: High Detail Red Clinker Soldier Course Fiber Brick Panels included. Brick Panels required for
operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is #44 and the Rear Burner Orifice Size is #38.
LPG INFORMATION
: An LP conversion kit is required to burn LPG in this appliance. Use either kit #AA-11-01257 or kit
#HA-42-00225 to convert this appliance to burn LPG. 12
”WC Minimum inlet pressure required. For the DXV45 DT4 LPG
application,
Front and Rear orifices are to be #53 (Rear) and 3/64” (Front). For higher altitude, adjustment to orifice size
may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION
: It is recommended that you run this Fireplace on maximum flame height,
for 3 cycles of 2 hours ON and 2 hours OFF, initially, to cure the paint. Some non-toxic smoking will be visible during the
cure cycles. It is recommended that all windows be opened during the first 2-hour burn cycle to expel the visible smoke.
BLOWER BREAK-IN PERIOD
: The integrated blowers in this Insert may exhibit some bearing noise and electrical static
noise during the first few days of operation. This is normal during the break-in period. It is recommended that following the
Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The burner flames must be on dur-
ing these cycles. The blowers in a few fireplaces may take longer to break-in and may require additional operation time
before all extraneous noise is eliminated. Please allow adequate operational time for the blowers to break-in before you
contact your dealer for service.