DMU380ZA Series
User’s Manual
________________________________________________________________________
Doc# 7430-3810 Rev. 02
Page 64
Digital Filter Settings
8.3
These two fields set the digital low pass filter cutoff frequencies (See Table 35). Each
sensor listed is defined in the default factory orientation. Users must consider any
additional rotation to their intended orientation.
Table 35 Digital Filter Settings
Filter Setting
Sensor
FilterGyro
Ux,Uy,Uz Rate
FilterAccel
Ux,Uy,Uz Accel
Orientation Field
8.4
This field defines the rotation from the factory to user axis sets. This rotation is relative to
the default factory orientation for the appropriate DMU380 family model. The default
factory axis setting for the IMU380ZA-200 orientation field is (-Uy, -Ux, -Uz) which
defines the connector pointing in the +Z direction and the +X direction going from the
connector through the serial number label at the end of the DMU380. The user axis set
(X, Y, Z) as defined by this field setting is depicted in Figure 18 below:
Figure 18 IMU380ZA-200 Default Orientation Field (
0x006B)
Table 36 DMU380 Orientation Definitions
Description
Bits
Meaning
X Axis Sign
0
0 = positive, 1 = negative
X Axis
1:2
0 = Ux, 1 = Uy, 2 = Uz, 3 = N/A
Y Axis Sign
3
0 = positive, 1 = negative
Y Axis
4:5
0 = Uy, 1 = Uz, 2 = Ux, 3 = N/A
Z Axis Sign
6
0 = positive, 1 = negative
Z Axis
7:8
0 = Uz, 1 = Ux, 2 = Uy, 3 = N/A
Reserved
9:15
N/A
There are 24 possible orientation configurations (See Table 37). Setting/Writing the field
to anything else generates a NAK and has no effect.
+Y
(-Ux)
+Z
(-Uz)
+X
(-Uy)
Pitch
Yaw
Roll