background image

D32802 | Date 11/2018  

5

Safety regulations

1.  Safety regulations

1.1  Terms and signs used

In this manual and on the appliance itself, certain common terms and signs are used to 

warn you of possible dangers or to give you hints that are important in avoiding injury or 

damage. Observe and follow these notes and regulations to avoid accidents and dam-

age. These terms and signs are explained below.

1.1.1  Terms used 

"Warning"

is used whenever you or somebody else could be injured if you do not 

observe the accompanying safety regulation.

"Caution"

is used for information that is important to avoid damage.

1.1.2  Signs used

Signs used

electrocu-

tion

Danger of 

explosion

Dangerous 

gases/va-

pours

Disconnect 

the mains 

plug

Observe infor-

mation in sepa-

rate manual

Important 

or useful 

additional 

information

1.2  Product safety and dangers

The appliances described in this manual are technically sophisticated, manufactured 

using high-quality materials and subject to many hours of testing in the factory. They 

reflect the state of the art and comply with recognised technical safety regulations. How-

ever, there are still risks involved, even when the appliances are used as intended. These 

are described below.

Warning! After removing covers, live parts may be exposed. Touch-

ing these can lead to an electrical shock. Disconnect the mains plug 

before removing any covers. Work on the electrical system must only 

be performed by qualifi ed electricians.

Warning! When loading the appliance with an unsuitable load, poi-

sonous or explosive vapours or gases may be produced. This could 

cause the appliance to explode, and people could be severely injured 

or poisoned. The appliance may only be loaded with materials/test 

objects which do not release any toxic or explosive vapours when 

heated (see also chapter Intended use on page  6).

Содержание HPPlife

Страница 1: ...www memmert com www atmosafe net 100 ATMOSAFE MADE IN GERMANY SUPPLEMENT TO THE OPERATING MANUAL CONSTANT CLIMATE CHAMBER HPP HPPlife ANIMAL KEEPING CHAMBER HPPlife...

Страница 2: ...E mail service memmert com For service enquiries please always specify the appliance number given on the type plate Shipping address for repairs Shipping address for repairs Memmert GmbH Co KG Custome...

Страница 3: ...functions described in this manual refer to the latest firmware version Due to individual configurations and sizes illustrations in this manual may be slightly dif ferent from the actual appearance F...

Страница 4: ...ption 8 2 2 Working range 2 2 Working range 2 2 Working range 8 2 3 Technical data 9 2 4 Scope of delivery 2 4 Scope of delivery 2 4 Scope of delivery 9 3 Putting into operation 10 3 1 Assembling the...

Страница 5: ...2 Product safety and dangers The appliances described in this manual are technically sophisticated manufactured using high quality materials and subject to many hours of testing in the factory They r...

Страница 6: ...for working with experimental animals are complied with is responsible for ensuring that unauthorised persons have no access to the appli ance is responsible for ensuring that the maintenance plan is...

Страница 7: ...ctions and irregularities The appliance may only be used in a flawless condition If you as the operator notice ir regularities malfunctions or damage immediately take the appliance out of service and...

Страница 8: ...more humidity Therefore use the central compressed air dehumidification see page 13 2 2 Working range The temperature humidity diagram Fig 2 specifies at what range of temperature and humidity a perm...

Страница 9: ...6 5 115 V 50 60 Hz 13 max number of sliding grids max 3 illuminated max load per sliding grid kg 30 max load per appliance kg 200 Temperature Adjustment range 0 C to 70 C Working range with illuminati...

Страница 10: ...it 2 2 Insert the exhaust air unit with the pipe socket into the entry port in the back of the chamber Fig 4 and attach it to the chamber with the eight Torx screws included Fig 5 Make sure that the e...

Страница 11: ...ompressed air dehumidification 3 3 Switching on the appliance Switch on the appliance by pressing the main switch on the front of the appliance Fig 8 The appliance displays are in English by default w...

Страница 12: ...y adjustment Setpoint and actual temperature display adjustment 3 Fan speed display Setpoint and actual temperature display Fan speed display Setpoint and actual temperature display 4 Activation key f...

Страница 13: ...limate chamber HPP for the adjustment options of the timer the programme operation tempera ture and humidity monitoring the graphical representation and the menu functions 4 3 Setting compressed air d...

Страница 14: ...ctory is 0 2 bar This is enough to achieve a certified dehumidification of 10 humidity at 10 C under laboratory conditions You can adjust the operating pressure after testing the appliance under the o...

Страница 15: ...0 fan speed 20 LED lighting and 22 C for 30 minutes Day simulation 60 fan speed 60 LED lighting and 22 C for 12 hours 5 Night simulation 0 LED lighting and 22 C for 11 hours with unchanged fan speed o...

Страница 16: ...emmert Stra e 90 96 D 91186 B chenbach Tel 49 9122 925 0 Fax 49 9122 14585 E Mail sales memmert com facebook com memmert family Die Experten Plattform www atmosafe net Animal keeping chamber HPPlife D...

Отзывы:

Похожие инструкции для HPPlife