background image

 D32802 | Date 11/2018  

3

About this manual

  About  this  manual

Purpose and target audience

This is a supplement to the operating instructions for the constant climate chamber HPP. 

This supplement amends the respective sections in the operating manual. If a specific 

section is not mentioned in this supplement, no changes are made to that section in the 

operating manual. 
The supplement describes the special functions of the animal keeping chamber HPPlife 

and is intended for use by trained personnel of the owner, who have the task of operat-

ing and/or maintaining the respective appliance. 
If you are asked to work on the appliance, read these instructions and the operat-

ing manual for the constant climate chamber HPP carefully before starting. Familiarise 

yourself with the safety regulations. Only perform work that is described in this manual. 

If there is something you do not understand, or certain information is missing, ask your 

manager or contact the manufacturer. Do not do anything without authorisation.

Versions

The functions described in this manual refer to the latest firmware version.
Due to individual configurations and sizes, illustrations in this manual may be slightly dif-

ferent from the actual appearance. Function and operation are identical.

Other documents that have to be observed:

The operating manual for the constant climate chamber HPP

For operation of the appliance with MEMMERT AtmoCONTROL, observe the separate 

software manual

For service and repair work, observe the separate service manual

Storage and resale

This operating manual belongs with the appliance and should always be stored where 

persons working on the appliance have access to it. It is the owner's responsibility to 

ensure that persons who are working on or are going to work on the appliance know 

where to find the operating manual. We recommend that it is always stored in a protect-

ed location close to the appliance. Make sure that the operating manual is not damaged 

by heat or humidity. If the appliance is resold or transported and then set up again at a 

different location, the operating manual must remain with it.
For the current version of this operating manual in PDF format, please go to 

http://www.memmert.com/en/service/downloads/user-manual/ .

Содержание HPPlife

Страница 1: ...www memmert com www atmosafe net 100 ATMOSAFE MADE IN GERMANY SUPPLEMENT TO THE OPERATING MANUAL CONSTANT CLIMATE CHAMBER HPP HPPlife ANIMAL KEEPING CHAMBER HPPlife...

Страница 2: ...E mail service memmert com For service enquiries please always specify the appliance number given on the type plate Shipping address for repairs Shipping address for repairs Memmert GmbH Co KG Custome...

Страница 3: ...functions described in this manual refer to the latest firmware version Due to individual configurations and sizes illustrations in this manual may be slightly dif ferent from the actual appearance F...

Страница 4: ...ption 8 2 2 Working range 2 2 Working range 2 2 Working range 8 2 3 Technical data 9 2 4 Scope of delivery 2 4 Scope of delivery 2 4 Scope of delivery 9 3 Putting into operation 10 3 1 Assembling the...

Страница 5: ...2 Product safety and dangers The appliances described in this manual are technically sophisticated manufactured using high quality materials and subject to many hours of testing in the factory They r...

Страница 6: ...for working with experimental animals are complied with is responsible for ensuring that unauthorised persons have no access to the appli ance is responsible for ensuring that the maintenance plan is...

Страница 7: ...ctions and irregularities The appliance may only be used in a flawless condition If you as the operator notice ir regularities malfunctions or damage immediately take the appliance out of service and...

Страница 8: ...more humidity Therefore use the central compressed air dehumidification see page 13 2 2 Working range The temperature humidity diagram Fig 2 specifies at what range of temperature and humidity a perm...

Страница 9: ...6 5 115 V 50 60 Hz 13 max number of sliding grids max 3 illuminated max load per sliding grid kg 30 max load per appliance kg 200 Temperature Adjustment range 0 C to 70 C Working range with illuminati...

Страница 10: ...it 2 2 Insert the exhaust air unit with the pipe socket into the entry port in the back of the chamber Fig 4 and attach it to the chamber with the eight Torx screws included Fig 5 Make sure that the e...

Страница 11: ...ompressed air dehumidification 3 3 Switching on the appliance Switch on the appliance by pressing the main switch on the front of the appliance Fig 8 The appliance displays are in English by default w...

Страница 12: ...y adjustment Setpoint and actual temperature display adjustment 3 Fan speed display Setpoint and actual temperature display Fan speed display Setpoint and actual temperature display 4 Activation key f...

Страница 13: ...limate chamber HPP for the adjustment options of the timer the programme operation tempera ture and humidity monitoring the graphical representation and the menu functions 4 3 Setting compressed air d...

Страница 14: ...ctory is 0 2 bar This is enough to achieve a certified dehumidification of 10 humidity at 10 C under laboratory conditions You can adjust the operating pressure after testing the appliance under the o...

Страница 15: ...0 fan speed 20 LED lighting and 22 C for 30 minutes Day simulation 60 fan speed 60 LED lighting and 22 C for 12 hours 5 Night simulation 0 LED lighting and 22 C for 11 hours with unchanged fan speed o...

Страница 16: ...emmert Stra e 90 96 D 91186 B chenbach Tel 49 9122 925 0 Fax 49 9122 14585 E Mail sales memmert com facebook com memmert family Die Experten Plattform www atmosafe net Animal keeping chamber HPPlife D...

Отзывы:

Похожие инструкции для HPPlife