Speech Language
English
Defaulted to the same as menu language.
French
German
Italian
Spanish
Japanese
Key Sounds
Off
Keypad sounds OFF/ON
On
Advanced
Top Diode
Sets which diode is the top (first) diode in the beam pattern
(1 to 6). This can be used to deactivate top diodes if they are
triggered by the door mechanism. Note that using this may not
be in compliance with EN81 requirements.
Bottom Diode
Sets which diode is bottom (last) diode in the beam pattern (12
to 48). Note that using this may not be in compliance with EN81
requirements.
Profile
10mm
G2510/G3510
43mm
G2540/G2510
Display
Status
Coded display of configuration and status - see below
Averages
Signal levels
Version
Firmware version
Access PIN
Future use
Serial Number
Serial number of controller
Firmware Ver.
Displays the firmware version.
Detector FW
Detector Firmware Version
Tx
Firmware version for each board in detector
Rx
Status Display:
The controller utilizes the LCD to show a coded status, so that common important settings can be observed at a glance.
This is also helpful for Avire service so they can get the configuration without going through menus.
The left hand side of the display shows status, the right hand side configuration
The format is as follows:
Digit
Meaning
1
‘2’ indicates 2D trigger
2
‘3’ indicates 3D trigger
3
If untriggered, 1 -3 indicate approximate distance in cm (max 250cm)
4
‘S’ detectors are in energy saving mode
5
‘T’ 1 or more diodes timed out, ‘t’ permanent trigger
6
‘:’ Separator between status and config
7
‘v’ if visible mode on
8
‘N’ visible normal, ‘D’ visible demo mode, ‘E’ visible external inputs, ‘T’ visible trigger