To remove the end covers simply lift upwards.
Power, relays and external door signals
Terminal No.
Function
Comments
1
Earth
85 to 240VAC if powered via AC (for DC use 17 & 18)
2
Neutral
3
Live
4
N/O
Relay 1 for door operator 250VAC, 24VDC at 5A
5
COM
6
N/C
7
N/O 1
Relay 2
8
COM 1
9
N/C 1
10
N/O 2
11
COM 2
12
N/C 2
13
D/C
Door closing input (12 to 230 AC/DC).
Note: not polarised
14
D/C
15
D/O
Door Opening input (12 to 230 AC/DC)
Note: not polarised
16
D/O
17
+
+15 to 48VDC if powered via DC
18
-
0V
8
11
7
9
10
12
Release clip for
end plate
Terminal 1
Fig 2: Connections
Fig 3: Installation
Recessed button
Table 1