BX 4000 Sereies Quick Start Guide
Mellanox Technologies
Rev 1
.5
3
The following downlink options are supported.
•
SFP+SR for Ethernet
•
SFP+LR for Ethernet
•
FC2/4/8G
Gateway Platform Installation and Operation
Installation and initialization of the gateway platform are straightforward processes, requiring attention to
the normal mechanical, power, and thermal precautions for rack-mounted equipment.
The gateway platform requires programming and configuration to operate as a basic InfiniBand to Ethernet,
Ethernet to Ethernet, or Ethernet to Fibre Channel gateway. The gateway platform includes all of the neces-
sary functionality to operate with external standard Subnet Management software when operating in Infini-
Band to Ethernet mode.
The following sections describe the installation process and basic operation of the gateway platform. Please
first read the warnings sub-section carefully before carrying on with installation procedures.
Installation Safety Warnings
For Safety Warnings in French and German and for special regulations regarding Finland, Sweden, Den-
mark, and Norway see the gateway user manual.
1. Installation Instructions
2. Over-temperature
3. Stacking the Chassis
4. Redundant Power Supply Connection - Electrical Hazard
5. During Lightning - Electrical Hazard
Read all installation instructions before connecting the equipment to the power
source.
This equipment should not be operated in an area with an ambient temperature
exceeding the maximum recommended: 45°C (113°F). Moreover, to guarantee
proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation
openings.
The chassis should not be stacked on any other equipment. If the chassis falls, it
can cause bodily injury and equipment damage.
This product includes a blank cover over the space for the redundant power sup-
ply. Do not operate the product if the blank cover is not securely fastened or if it
is removed.
During periods of lightning activity, do not work on the equipment or connect or
disconnect cables.