BX 4000 Sereies Quick Start Guide

Mellanox Technologies 

Rev 1

    12      

Change Your Password

NOTE: Managing the BX4000 cannot be done with root privileges. As such, you need to prefix all 

 

SSH/Telnet commands with 'sudo'.

1. Enter the command

sudo passwd admin

You will be asked to put in your password in order to use the sudo command. The sudo command permis-
sions expire periodically (usually after 5 minutes by default). See man sudo for more information.

2. Enter your new password.

Make sure the password contains upper and lower case letters, numbers, and symbols. 

Note: If your password does not contain all of the above you will get the following warning 

 

“BAD PASSWORD: it is based on a dictionary word”.

3. Reenter the password for confirmation.
You will be asked for your password whenever you open new connection, or when you run a sudo command.

The “sudo” command will ask for your password each time you run it. If you logout from 
the current session or if it closes by timing out (10 min.), you will be asked for your pass-
word again. 

Network Configuration

The only allowed user name is “admin”.

For Networking configuration: 

1. Run the following command as admin:

# sudo config_net

The following menu will appear.

1) Configure Host Networking
2) Configure IP Address
3) Configuration for Host Networking and IP Address
4) Exit

2. Enter Your Selection:

The current HOST configuration will be displayed and you will be asked if you want to change it.

Configure Host Networking 

Selection 1 under the config_net brings you to this flow. It will show the current configuration and ask if you 
want to change it.

Configure Host Networking - 
The current HOST configuration is:
NETWORKING=yes
NETWORKING_IPV6=no
GATEWAY=<IP_ADDRESS>
HOSTNAME=<hostname.domainname>
Do you want to change this configuration? [y/N]: (Default “No”)

Y – will open the following flow:

Содержание BX4000 Series

Страница 1: ...orresponding downlink ports Each gateway port group is assigned a color to easily associate the uplink ports to the corresponding downlink ports of the gateway port group Figure 1 MTB 4010 Gateway Por...

Страница 2: ...k ports per gateway port group These ports have SFP connectors that support both direct attach copper cable and optical cables by using a SR or LR modules The downlink ports are labelled alpha numeric...

Страница 3: ...carrying on with installation procedures Installation Safety Warnings For Safety Warnings in French and German and for special regulations regarding Finland Sweden Den mark and Norway see the gateway...

Страница 4: ...system remains stable In general you should fill the rack with equipment starting from the bottom to the top This equipment should be installed replaced or serviced only by trained and qualified perso...

Страница 5: ...de All connectivity is via the connector side panel All connectors can support active cables Figure 3 MTB4010B Gateway System Power Side and Connector Side Panels Package Contents The package should i...

Страница 6: ...en sent check this against the parts list Check the parts for visible damages that may have occurred during shipping Note If anything is damaged or missing contact your customer representative immedia...

Страница 7: ...ck and the door can be as little as 4 cm on one side of the rack and as much as 18 cm on the other side of the rack Keep in mind that there can be as many as 10 cables for the MTB4010B onnected to the...

Страница 8: ...he rails Figure 6 Clipping in the Caged Nuts 4 Using two of the pan head screws and one washer for each rail install the rails to the end of the rack Place the rail behind the holes in the rack and sc...

Страница 9: ...irmly seated The GREEN LED indicator above of each CX4 ports or above or below each SFP port will light when the physical connection is established that is when the unit is powered on and a cable is p...

Страница 10: ...ions Access through Serial Port 1 Connect the host PC to the RS 232 port of the MTB4000 series gateway using the supplied cable 2 Make sure to connect to the RS 232 RJ 45 port of the switch and not to...

Страница 11: ...PU Ethernet port to your local 1Gigabit Ethernet network 2 Connect any Linux station to the Ethernet 3 At the prompt enter ssh admin 172 22 2 2 4 Enter the password Password admin Access through Telne...

Страница 12: ...when you run a sudo command The sudo command will ask for your password each time you run it If you logout from the current session or if it closes by timing out 10 min you will be asked for your pas...

Страница 13: ...n it will implement the current configuration and ask you if you want to change the IP address configuration Do you want to configure IP Address Y n Default Yes N will redirect you to the main menu Y...

Страница 14: ...es After completing these selections the selected configuration will be displayed and you will be asked if you want to save it Selected configuration DEVICE eth0 BOOTPROTO static IPADDR IP_ADDRESS NET...

Страница 15: ...or full use of FabricIT The standard management module without a license allows for managing the gateway using the Web interface or the com mand line interface and software supplied on the management...

Отзывы: