6. Copper InfiniBand Cable Connecting/Disconnecting
7. Rack Mounting and Servicing
8. Equipment Installation
9. Equipment Disposal
10. Local and National Electrical Codes
11. Hazardous Radiation Exposure
12. UL Approved AC Power Cords
Mechanical Installation
The gateway platform can be rack mounted for installation in a standard 19” rack. Power side and connector
side are arbitrary, the rack kit can be mounted so that one side is even with the vertical rack support and the
other side is recessed into the rack. For convenience we will use the terms power side of the gateway to
Copper InfiniBand cables are heavy and not flexible, as such they should be
carefully attached to or detached from the connectors. Refer to the cable manu-
facturer for special warnings and instructions.
When this product is mounted or serviced in a rack, special precautions must be
taken to ensure that the system remains stable. In general you should fill the
rack with equipment starting from the bottom to the top.
This equipment should be installed, replaced, or serviced only by trained and
qualified personnel.
Disposal of this equipment should be in accordance to all national laws and reg-
ulations.
This equipment should be installed in compliance with local and national elec-
trical codes.
Caution – Use of controls or adjustment or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
CLASS 1 LASER PRODUCT and reference to the most recent laser standards:
IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+
A2:2001
For North American power connection, select a power supply cord that is UL
Listed and CSA Certified 3 - conductor, [18 AWG], terminated in a molded on
plug cap rated at 125 V, [15 A], with a minimum length of 1.5m [six feet] but no
longer than 4.5m.
For European connection, select a power supply cord that is internationally har-
monized and marked "<HAR>", 3 - conductor, minimum 0,75 mm2 wire, rated
at 300 V, with a PVC insulated jacket. The cord must have a molded on plug cap
rated 250 V, 10 A.