![Melec C-875 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/melec/c-875/c-875_instruction-manual_1767048061.webp)
- 61 -
8.DETAILS
OF
COUNTER
FUNCTIONS
The following description is given about the X axis, but also applicable to the Y axis,Z axis and A axis.
8-1. Functional Block Diagram
The MCC05v2 has three built-in 24-bit HARD COUNTERs each provided with different functions.
COUNTER
<XEA,XEB(External clock)
Set data
DATA1,2,3
<XCWP,XCCWP(Output pulse)
WRITE PORT
PULSE COUNTER
PULSE COUNTER PRESET
INITIALIZE Command
(COUNTER Command)
24BIT PULSE COUNTER
COUNT PATTERN TYPE
PULSE COUNTER
INITIALIZE Command
Count data
INT CONTROL
24BIT COMPARATOR × 5ch
XCNTINT OUTPUT
PULSE COUNTER
INITIALIZE Command
24BIT COMPARE
REGISTER × 5ch
COMP1~5 REG SET
(COUNTER Command)
DFL COUNTER
DFL COUNTER PRESET
INITIALIZE Command
(COUNTER Command)
ADRS/DFL/PULSE
COUNTER PORT
SELECT Command
24BIT DIFFERENTIAL COUNTER
COUNT PATTERN TYPE
DFL COUNTER
INITIALIZE Command
DRIVE
Differential data
SELECTOR
DATA1,2,3
READ PORT
INT CONTROL
24BIT COMPARATOR×2ch
XDFLINT OUTPUT
DFL COUNTER
INITIALIZE Command
24BIT COMPARE
REGISTER×2ch
COMP1~2 REG SET
(COUNTER Command)
Address data
24BIT ADDRESS COUNTER
ADDRESS INITIALIZE Command
DRIVE
To another functional block
24bit data
DATA1,2,3
WRITE PORT
Содержание C-875