![Melec C-875 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/melec/c-875/c-875_instruction-manual_1767048048.webp)
- 48 -
6-28.SCSPD1 ADJUST Command
COMMAND………
65
Function : Adjusts SCSPD1 (linear RATE start speed or linear RATE end
H
speed) required for S-RATE DRIVE.
Execution sequence
SCSPD1 is set in DRIVE DATA1 PORT, DRIVE DATA2 PORT and DRIVE DATA3 PORT
in 3-byte data in Hz.
N
BUSY=0 in
The contents of DRIVE DATA1 PORT to DRIVE DATA3 PORT are as follows.
STATUS1?
DATA1 PORT
DATA2 PORT
DATA3 PORT
7
0
7
0
7
0
Y
D
D
D
D D
D
DATA1 PORT
WRITE
The order
DATA2 PORT
may not
SCSPD1 DATA
WRITE
be observed.
SCSPD1 is reset to the value indicated by the following expression
DATA3 PORT
at POWER ON/RESET or by the SLSPD SET command or SHSPD SET command.
WRITE
When the specification is satisfied with the following data,
this command does not need to be executed.
COMMAND 65
1
H
SCSPD1=SLSPD+(SHSPD-SLSPD)×
WRITE
3
Note1: After the SLSPD SET command or the SHSPD SET command is executed, SCSPD1 set prior to the execution
becomes ineffective and is reset to the initial value.
This is also applicable to the case in
which DRIVE TYPE has been changed by the SPEC INITIALIZE1 command.
Note2: The SCSPD1 adjusting range is SLSPD≦SCSPD1≦SCSPD2.
When SCSPD1<SLSPD is specified, SCSPD1 becomes equal to SLSPD.
When SCSPD1>SCSPD2 is specified, SCSPD1 becomes equal to SCSPD2.
6-29.SCSPD2 ADJUST Command
COMMAND………
66
Function : Adjusts SCSPD2 (linear RATE end speed or linear RATE
H
start speed) required for S-RATE DRIVE.
Execution sequence
SCSPD2 is set in DRIVE DATA1 PORT, DRIVE DATA2 PORT and DRIVE DATA3 PORT
in 3-byte data in Hz.
N
BUSY=0 in
The contents of DRIVE DATA1 PORT to DRIVE DATA3 PORT are as follows.
STATUS1?
DATA1 PORT
DATA2 PORT
DATA3 PORT
7
0
7
0
7
0
Y
D
D
D
D D
D
DATA1 PORT
WRITE
The order
DATA2 PORT
may not
SCSPD2 DATA
WRITE
be observed.
SCSPD2 is reset to the value indicated by the following expression
DATA3 PORT
at POWER ON/RESET or by the SLSPD SET command or SHSPD SET command.
WRITE
When the specification is satisfied with the following data,
this command does not need to be executed.
COMMAND 66
2
H
SCSPD2=SLSPD+(SHSPD-SLSPD)×
WRITE
3
Note1: After the SLSPD SET command or the SHSPD SET command is executed, SCSPD2 set prior to the execution
becomes ineffective and is reset to the initial value.
This is also applicable to the case in
which DRIVE TYPE has been changed by the SPEC INITIALIZE1 command.
Note2: The SCSPD2 adjusting range is SCSPD1≦SCSPD2≦SHSPD.
When SCSPD2<SCSPD1 is specified, SCSPD2 becomes equal to SCSPD1.
When SCSPD2>SHSPD is specified, SCSPD2 becomes equal to SHSPD.
Содержание C-875