Fig. 50: Spanner flats
11.
Position the process connection
(inlet) so that the spanner flats
(Fig. 50/1) are at a 90
°
angle to
the sight glass scale. The
locating pin hole on the process
connection must be centered on
the front of the device housing
locating screw.
Fig. 51: Insert the process connection
into the device housing
12.
Insert the process connection
(inlet) with the inner section into
the device housing (Fig. 51) and
axially align the connection to
the housing. The locating pin
hole in the process connection
must be centered to the front
locking screw of the device
housing
Fig. 52: Secure the process connec-
tion (inlet)
13.
Secure the inlet process con-
nection with 3 hex socket
screws (Fig. 52/1) to the device
housing, observing the proper
torque
14.
Rotate the device 180
°
Maintenance
Maintenance > Assembly
03.09.2018
DWG Module BASICS Flow Monitor