This Setup Guide is a systematically structured guideline which supports you during the set-up of your Mein-
berg product.
The IMS-MRI (MRI=Multi Reference Input) provides four signal inputs: 1x Time Code AM, 1x Time Code
DCLS, 1x 10 MHz as well as 1x PPS. These input signals are made available to the IMS system as additional
reference signals. The signals can be monitored and selected in the "Clock" menu of the assigned clock module
after successful initialization.
Features
.
As already mentioned above, an MRI module is assigned to a clock module and provides it with additional
reference signals. If additional reference signals should also be available for the second clock module in re-
dundant operation, it is necessary to add another MRI module for this purpose.
Example:
1x GPS Clock on
CLK1
requires 1x MRI on
MRI1
1x GPS Clock on
CLK1
and 1x GNS Clock on
CLK2
requires 1x MRI on
MRI1
and 1x MRI on
MRI2
The LTOS manual provides a complete description of all configurations and status monitoring options of your
Meinberg product.
Download LTOS7 Firmware manual:
http://www.mbg.link/doce-fw-ltos
Compatibility
The IMS-MRI is an IMS module that is compatible with the following systems of the IMS family and can
be used in the slots shown in the table down below.
PWR
CLK
CPU
MRI
ESI
I/O
M500
M1000
M1000 S
M2000 S
M3000
M3000 S
M4000
System Compatibility - IMS MRI
IMS System
Compatible
Compatible
IMS Slot
Slot Compatibility - IMS MRI
IMS-MRI
Date: March 21, 2022
3