7.2 AM Time Code (Modulated) Input
Input Signal:
Unbalanced Sine Wave Signal
Input Type
Fiber optic (FO), Multi mode
Time Code Signals:
B122/123, B126/127
IEEE1344
C37.118
AFNOR NFS 87-500
Wave lenght
850 nm
Min. Input Power:
3
µ
W
To ensure reliable signal detection, the input signal
should not fall below the specified value
.
Connector Type:
ST Connector
Type of fiber:
GI 50/125
µ
m or
62,5
µ
m gradient fibre
7.3 Time Code DCLS (unmodulated) Input
Input Signal:
Time code DCLS, pulse width modulated.
(e.g. IRIG-B00x)
Input Type:
Fiber Optic (FO), Multimode
Time code signals:
B002/003, B006/007
IEEE1344
C37.118
AFNOR NFS 87-500
Wave length:
850 nm
Min. input power:
3
µ
W
To ensure reliable signal detection, the input signal
should not fall below the specified value
.
Connection type:
ST connector.
Fiber type:
GI 50/125
µ
m or
62.5/125
µ
m gradient fiber