5 MRI Variants
5 MRI Variants
The MRI module (MRI = Multi-Reference Input) is available in a number of different models. The standard
MRI modules provide the following signal input connectors, depending on the model in question:
MRI
4x BNC
TC AM, TC DCLS, 10 MHz, PPS
MRI-FO
4x ST
TC AM, TC DCLS, 10 MHz, PPS
MRI-FO-T
2x ST, 2x BNC
TC AM, TC DCLS (ST) / 10 MHz, PPS (BNC)
The MRI-FO model is especially well-suited to transmission of MRS signals over long distances, with the
transmission of MRS signals over fiber-optic cable also making it much less susceptible to interference.
Before the amplitude-modulated IRIG AM signal can be fed into the FO input, it must first be
generated using a Meinberg
"CON/TCM/FO"
converter.
MRI
MRI-FO
MRI-FO-T
Technical Specifications of the MRI Module
Electrical Connector:
DIN 41612 96-Pin Connector
Operating Voltage:
+5 V DC
Current Draw:
100 mA
Temperature Range:
0–50
◦
C / 32–122
◦
F
Relative Humidity:
Max. 85%
IMS-MRI
Date: March 21, 2022