5 ANZ14 (NET Option)
5.7.5 Menu Option 4: Reserved
This menu is reserved for future purposes.
5.7.6 Menu Option 5: Time Zone Configuration
Select 5 to configure the ANZ14’s time zone settings. The NTP time is a linear time scale similar to UTC,
without information about the time zone. This menu lets the user enter the range of date for daylight saving to
be in effect as well as the local times’s offset
to UTC.
Start and end of daylight saving is defined by dates, used by an algorithm which allows the ANZ14 to re-
compute the effective change-over dates year by year. Starting from the configured date, daylight saving
changes the first day which matches the configured day-of-week. For example March 25, 2009 is a Wednesday,
so the next Sunday is March 29, 2009.
5.7.7 Menu Option 6: NTP Client Configuration
Select
6
to enter the ANZ14’s NTP configuration.
NTP Server
The IP address of up to three NTP servers can be entered here. First the first NTP server is tried to achieve.
If this fails, the second and than the third NTP server is queried. In case of 0.0.0.0 is entered for the first NTP
server, the ANZ14 tries to find a NTP server itself.
ANZ14 inquires the time information from the NTP server and sets its own freerunning clock. The NTP
request time is set to 64sec.
Display Delay Time
This value causes the ANZ14 to display the time delayed. It should be set to zero because of the internal
compensation of the propagation time.
NTP Client Stratum
A NTP stratum can be assigned to the ANZ14. If the NTP server has a higher stratum during the request than
the ANZ14, the time infomation is rejected.
5.7.8 Menu Option 7: Factory Defaults
You can reset your configuration by choosing this option. Please note that network parameters are not altered
(you have to change them manually by using Menu Option 1). If you have chosen this option by accident, just
abort the Telnet Session by using Menu Option 7 and reconnect.
5.7.9 Menu Option 8: Exit without save
If you changed something by accident or did not change anything, you can leave the Telnet setup by choosing
this option. The telnet session is closed without saving the changes and without a reboot.
5.7.10 Menu Option 9: Save and exit
All parameters are saved in the nonvolatile memory of the module and afterwards the unit restarts in order to
put the changes into effect. After 10 – 30 seconds the ANZ14 module has finished rebooting and can be used
again.
ANZ14/ANZ14DCF/ANZ14NET