2 Safety Hints

 

AC Power Supply 

DC Power Supply 

 

The  device  is  a  device  of  protection  
class  1  and  may  only  be  connected to  a 
grounded outlet (TN system). 

 

For  safe  operation,  the  device  must  be 
protected  by  an  installation  fuse  of  max.  
16 A and equipped with a residual current 
circuit  breaker  in  accordance  with  the 
applicable national standards. 

 

The unit must always be disconnected from 
the mains and not from the appliance. 

 

Devices  with  mains  plugs  are  equipped 
with  a  safety-tested  mains  cable  of  the 
country of use and may only be connected 
to a grounded shockproof socket, otherwise 
electric shock may occur. 

 

Make  sure  that  the  mains  socket  on  the 
appliance or the mains socket of the house 
installation is freely accessible to the user 
so that the mains cable can be pulled out 
of the socket in case of emergency. 

 

Outside  the  assembly  group  the  device  must  be 
disconnectable  from  the  power  supply  in 
accordance  with  the  provisions  of  IEC  60950-1 
(e.g. by the primary line protection). 

 

Installation and disassembly of the power supply 
plug  is  only  permitted  if  the  assembly  group  is 
switched off (e.g. by the primary line protection). 

 

The supply lines must be adequately secured and 
dimensioned. 
 

Connection Cross Section: 
  1 mm

2

 

 2.5 mm

2

  

 

 

  17 AWG 

 13 AWG 

 

 

The device must be supplied with a suitable 
disconnector (switch). The separation device must 
be easily accessible, placed near the device and 
marked as a separation device for the unit. 

 

ANZ14/ANZ14DCF/ANZ14NET

Date: 28th October 2019

7

Содержание ANZ14

Страница 1: ...MANUAL ANZ14 ANZ14DCF ANZ14NET LED Display with DCF77 or NTP Option 28th October 2019 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...Mounting the Antenna 16 5 ANZ14 NET Option 17 5 1 Network Time Protocol NTP 17 5 2 Time and Date Display with NTP synchronized Reference 17 5 3 Error Code 18 5 4 Network Configuration 18 5 5 DHCP 19 5...

Страница 4: ...9 Technical Specifications ANZ14 33 9 1 Rear Panel Connectors 34 9 1 1 Pin Assignment of the D SUB Connectors COM0 COM1 34 9 2 Rear Views 35 9 3 Time Strings 36 9 3 1 Format of the Meinberg Standard T...

Страница 5: ...kuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2014 06 20 ANZ14 ANZ14DCF AN...

Страница 6: ...ue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminently hazardou...

Страница 7: ...ischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blades IEC 60417...

Страница 8: ...for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the insta...

Страница 9: ...on in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until the unit is...

Страница 10: ...rly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure that...

Страница 11: ...ket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside the assembly gr...

Страница 12: ...there is a danger of overheating during operation Disturbances during operation can result Normal Operation The normal operation and the observance of the EMC limits electromagnetic compatibility are...

Страница 13: ...risks for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not...

Страница 14: ...e dangers to the user e g electric shock Liquid can destroy the electronics of the device Liquid penetrates into the housing of the device and can cause a short circuit of the electronics Only clean w...

Страница 15: ...t when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity Transporting Assemblies As...

Страница 16: ...duct symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specific...

Страница 17: ...lfunction A power fail comparator resets the microprocessor if the supply voltage drops below a specified threshold A flash EPROM located in the microprocessor is used as program memory that can be lo...

Страница 18: ...a time string once per second once per minute or only on request by sending an ASCII character ASCII code 3Fh 3 6 Power Supply The integrated mains power supply provides the clock with a stabilized vo...

Страница 19: ...to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute will begin with the next time mark Our radio remote clocks decode the highly accu...

Страница 20: ...ed at least 30 centimeters away from the clock unit and from solid steel A distance of several meters is recommended to all TVs or computer monitors In order to get the maximum signal the antenna shou...

Страница 21: ...syncronization is feasible because of the several time references Every computer syncronizies itself by up to three valued time sources NTP enables the comparison of the hardware times and the adjust...

Страница 22: ...0 internal error Er 01 no answer from NTP Er 02 NTP not synchronized Er 03 NTP stratum stratum of ANZ14 Er 04 05 for debugging only 5 4 Network Configuration To identify the ANZ14 in the network it is...

Страница 23: ...ardware address of the Device Server which is found on the label beside the RJ45 connector in the rear panel In order for the ARP command to work on Windows the ARP table on the PC must have at least...

Страница 24: ...you are presented the Welcome message and have to enter the access password If the password has been entered correctly you have to press enter again to start the setup tool Meinberg XPort Display MAC...

Страница 25: ...cond part of your IP address and confirm it with RETURN Afterwards you can enter the third and finally the fourth part of the address After entering all four parts the screen looks like this IP Addres...

Страница 26: ...e rwpublic An incoming SNMP request coming with this community string is granted read writeaccess meaning you can change a value At the moment there are no variables accessible for write access so thi...

Страница 27: ...ver itself ANZ14 inquires the time information from the NTP server and sets its own freerunning clock The NTP request time is set to 64sec Display Delay Time This value causes the ANZ14 to display the...

Страница 28: ...ed literature An OID looks like this 1 3 6 1 4 1 5597 20 2 2 All Meinberg units can be found under the 1 3 6 1 4 1 5597 branch the 5597 represents the unique world wide used enterprise ID of Meinberg...

Страница 29: ...University of Delaware September 1989 Mills90 Mills D L Network Time Protocol Version 3 specification implementation and analysis Electrical Engineering Department Report 90 6 1 University of Delawar...

Страница 30: ...e valid until the configuration is saved in the last sub menu of the setup menu 6 2 Brightness Br The brightness of the display can be set in steps from 0 to 9 where 0 represents the most dimmed brigh...

Страница 31: ...sub menu The baud rate of the serial interface COM0 and COM can be set in this sub menu Button B is used to select one of the available baud rates button A is pressed to leave this and enter the next...

Страница 32: ...llowing order CET Central European Time or CET EET East European Time or UTC without DST This setting is only relevant in the case of a DCF77 synchronized ANZ14 In case of a serial or NTP synchronized...

Страница 33: ...IS 5 SAT 7 Computime The format of the strings is described in the chapter Time Strings 6 14 Serial Number SN The 16 digit serial number of the ANZ14 can be displayed in this menu The first 4 digits a...

Страница 34: ...are rejected if YES is choosen with button B 6 17 Save Sv All changes made in the setup menu have to be saved before coming into effect so this sub menu has to be left with button A while YES is show...

Страница 35: ...e ANZ14 time that is running free from this moment The ANZ14 keeps synchronisation to the master clock if the time string comes periodically once per second or once per minute This time string is spre...

Страница 36: ...ootstrap loader of the microprocessor which is waiting for commands via the serial interface COM0 is activated Subsequently the new software can be transferred from any PC with a serial interface The...

Страница 37: ...D and a status character in the serial output string Without RF signal the clock runs on XTAL with an accuracy of 10 6 after 24 hours of synchr operation indicated by LED Free run accuracy ANZ14NET 3...

Страница 38: ...D RS232 RS422 shielded data line Antenna BNC 77 5 kHz shielded coaxial cable Power supply power cord receptacle 100 240 V AC cold device power plug or DFK connector 12 V or 24 V DC 2 wire 0 5mm2 min...

Страница 39: ...M0 COM1 ANZ14 DCF with 240 VAC 50 60Hz Power Supply Antenna T1A 250V COM0 COM1 ANZ14 DCF with DC Power Connector Power 230V SB0 2A 250V ETH LTRX XPORT MAC Addr xxxxxxxxxxxx COM0 COM1 ANZ14 NET with Ne...

Страница 40: ...ck status characters depending on clock type u GPS clock is running free without exact synchr PZF time frame not synchronized DCF77 clock has not synchronized after reset space 20h GPS clock is synchr...

Страница 41: ...ile leap second v sign of the offset of local timezone related to UTC oo oo offset of local timezone related to UTC in hours and minutes ac clock status characters a clock has not synchronized after r...

Страница 42: ...ng characters are possible N north of equator S south d equator lll llll longitude of receiver position in degrees leading signs are replaced by a space character 20h e longitude the following charact...

Страница 43: ...tor of message ASCII 0 code 30h TSQ Telegram number ASCII 0 code 30h CC Command code ASCII S for SET code 53h CS Command code ASCII A for ALL code 41h ST Time status ASCII C for valid time code 43h yy...

Страница 44: ...mm ssq CR LF The letters printed in italics are replaced by ASCII numbers whereas the other characters are part of the time string The groups of characters as defined below SOH Start of Header ASCII...

Страница 45: ...2 yy year of the century 00 99 w the day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second xxxx time zone indicator UTC Univer...

Страница 46: ...ters are part of the time string The groups of characters as defined below jj mm tt the current date jj year of the century 00 99 mm month 01 12 tt day of month 01 31 _ Space ASCII code 20h hh mm ss f...

Страница 47: ...II numbers whereas the other characters are part of the time string The groups of characters as defined below T Start character sending with one bit accuracy at change of second yy mm dd the current d...

Страница 48: ...ions of seconds 1 10 1 100 A Status A time data valid V time data not valid The following information regarding the receiver position is set to zero because receiver does not support this bbbb bb lati...

Страница 49: ...das sich diese Erkl rung bezieht mit den folgenden Normen und Richtlinien bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives...

Отзывы: