3.4 Display
The 14-digit LED display shows the time, date and day-of-week. The displays brightness is variable and
configurable via menu.
3.5 Serial Interface
The ANZ14 provides two serial ports which can either be used as RS232 or RS422 interfaces. The COM0
interface provides an RS422 output, COM1 provides an RS422 input. On this way, a ANZ14 with DCF receiver
can synchronize an additional ANZ14 without receiver. The transfer rate and the data format are free selectable.
The serial port can sent a time string once per second, once per minute or only on request by sending an ASCII
character ’?’ (ASCII code 3Fh).
3.6 Power Supply
The integrated mains power supply provides the clock with a stabilized voltage of 5V. The standard AC power
supply has an input range of 100-240V/50-60Hz and is fused with T 0.2 A / 250 V. The DC versions are fused
with T 1 A.
The supply voltage is fed to the receiver via a connecting socket in the back of the device. The clock has
no power switch and therefore will start immediately. Depending on the supply voltage (see label on the case)
the ANZ14 is equipped with an IEC socket (AC) or with a 3pin. terminal connector (DC).
14
Date: 28th October 2019
ANZ14/ANZ14DCF/ANZ14NET
Содержание ANZ14
Страница 2: ......