Single: Individual values can be read or written in this operating
mode.
Interrupt: For the interrupt handling in the bit-pattern change
mode (see chapter 4.2.1 starting on page 26).
Operation Mode
Speed
Trigger
Single
single value
input/output via software
Interrupt (bit-pat-
tern detection)
f
IRQmax.
= 10
kHz
ext. trigger signal at a
digital input/output port
4.1 Single Operation Mode
Individual values can be read or written in this operating mode.
Notes:
The digital-I/O channels direction is determined by the ME-5004
series hardware (opto-couplers).
In power-down state and after switching on the PC all outputs
are in a high-impedance state. Only if “1” is written, the output
changes to conductive.
A port that is configured as an output can also be read back!
4.1.1 Digital Input/Output
For input/output of individual digital values the single operation
mode is used. The subdevices are defined as follows: subdevice 0 is
always of type ME_TYPE_DI and subdevice 1 of type ME_TYPE_DO.
The sub-type is always ME-SUBTYPE_SINGLE.