3.2 ME-5004 cPCI/PCIe
3.3 Digital Input/Output
The opto-isolated inputs and outputs have been designed for appli-
cations in industrial control applications (typ. 24 V). An external
power supply (pin: VCC_EXT) is required for the opto-isolated digital
outputs. Depending on the application, the drivers of the output
ports can be configured as sink or source or high impedance via
software. The isolation voltage to PC ground is 1000 VAC
RMS
.
The plug-on board of type ME-5004 has 16 opto-isolated inputs
and 16 opto-isolated outputs. Due to the opto-isolation, the port
direction is fixed.
The programming of the various operating modes is described in
chapter 4.1 from page 22.