![MEIG SLM550 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/meig/slm550/slm550_hardware-design-manual_1765891072.webp)
MeiG_SLM550_Hardware Design Manual
MeiG Smart Technology Co., Ltd
71/89
6 Electrical, Reliability
6.1 Absolute Maximum
The table below shows the absolute maximum values that the module can withstand. Exceeding these
limits can cause permanent damage to the module.
Table 17 Absolute Maximum
Parameter
Minimum
Typical
Maximum
Unit
VBAT
-
-
6
V
VBUS
-
-
10.5
V
Peak current
-
-
3
A
6.2 Working Temperature
The table below shows the operating temperature range of the module:
Table 18 Module Operating Temperature
Parameter
Minimum
Typical
Maximum
Unit
Working temperature
-25
-
75
℃
Storage temperature
-40
-
90
℃
6.3 Working Voltage
Table 19 Module Operating Voltage
Parameter
Minimum
Typical
Maximum
Unit
VBAT
3.4
4.2
V
VBUS
4
5
6
V
Hardware shutdown voltage
2.5
2.8
-
V