Red LED is flashing and
no coins are accepted
Check Route Alpha addresses 340
to 349 for a description of the error
The cover of the acceptor is not
closed firmly
The acceptor loom is not connected
The coin path in the acceptor is dirty
Switch off power to the machine and open and close the lid
of the acceptor. Make sure the lid snaps shut firmly. Wait at
least 15 seconds and switch the power on again.
Check the acceptor loom and reconnect it if necessary.
Switch off the power to the machine and clean the acceptor.
Red LED is
off, but
change coins are routed to
the cashbox and not to the
tubes
Mismatch between the true coin
count in a tube and the count being
registered by the unit
Press and hold down A, B and C for at least three seconds to
dispense coins down to the tube safe counts, then re-float the
tubes.
Press Mode + A + B, and insert change coins through the
acceptor until tubes reach their pre-set levels
Red LED is off
permanently, with no
other problems present
Faulty LED or keypad module
Check and replace the keypad module if it is faulty. Refer to
your authorised MEI distributor.
Problem
Causes
Actions