, MEI., 1996
17
CashFlow
®
520 changegiver Pocket Guide
Setting a Unit’s Functions with a
MEI
s
Route Alpha 250 Terminal
Each piece of data which determines the unit’s
functions is stored in a separate address. Use the
terminal to read an address and to check or set the
unit’s functions.
Setting Functions
Insert the plug on the Route Alpha 250 terminal
into the six-way connector in the acceptor unit
.
A half-size zero is displayed when the terminal
powers up, followed by the software version
number and then the first address number with a
dot, or a dot and dash (1. or 1.-)
Functions can be changed only if a dash shows
after the address number.
Press UP or DOWN slowly to display addresses
one after the other. Hold down a key to display
addresses at an increasing speed. Press a key
twice quickly to jump large blocks of addresses.
To set a function, press ENTER to show the current
value in the selected address, then change the
value by pressing UP or DOWN.
Press ENTER again to return to the address
display. Press RESET to store the new value.
NOTE:
If an error occurs, four half-size zeros
appear. Press RESET to clear this display and to
return to the current address.
LEFT
UP
RIGHT
DOWN
ENTER
Six-way
connector
RESET
Display