CashFlow
®
520 changegiver Pocket Guide
20
,
MEI., 1996
229
Inhibit coin: coins 1 to 4
0 - 15
Address value = the sum of the codes where:
Code 0 = no coins inhibited
Code 1 = inhibit coin 1 Code 4 = inhibit coin 3
Code 2 = inhibit coin 2 Code 8 = inhibit coin 4
To inhibit more than one coin at the same time, add
their codes together.
For example, codes 1 + 8 = 9. If you choose 9 for this
address range value, coins 1 and 4 will be inhibited.
230
Inhibit coin: coins 5 to 8
0 - 15
Address value = the sum of the codes where:
Code 0 = no coins inhibited
Code 1 / 2 / 4 / 8 = inhibit coin 5 / 6 / 7 / 8
231
Inhibit coin: coins 9 to 12
0 - 15
Address value = the sum of the codes where:
Code 0 = no coins inhibited
Code 1 / 2 / 4 / 8 = inhibit coin 9 / 10 / 11 / 12
Not MDB
232
Inhibit exact change group
Inhibit coins 1 - 4
0 - 15
Code 1 / 2 / 4 / 8 = inhibit change coin 1 / 2 / 3 / 4
Not MDB
Address
Parameter
Range
Meaning
Notes