MEI., 1996
13
CashFlow
®
520 changegiver Pocket Guide
Yellow LED is off
Normal operation
No action
Yellow LED flashes when
coins are accepted
Normal operation
No action
Yellow LED remains off
when the Mode button is
pressed
No power supply to the vending
machine
Switch off power to the machine, check all looms and check
all fuses.
Replace blown fuses, following the instructions in this Pocket
Guide.
Yellow LED is flashing
The changegiver is in shifted mode
because the Mode button has been
pressed
The keypad is available to change the functions of the unit.
(Press Mode or wait for 45 seconds to exit from shifted mode).
Yellow LED is off
permanently.
No other problems present
Faulty LED or keypad module
Check the keypad module. If faulty, refer to your MEI distributor.
Problem
Causes
Actions