![Megmeet MTC-08-NT Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/megmeet/mtc-08-nt/mtc-08-nt_user-manual_1765700012.webp)
12
BFM
Content
Remarks
Nat
ure
Sa
ve
CH1/CH5
CH2/CH6 CH3/CH7 CH4/CH8
#1165/#11
69
#1166/#11
70
#11671171 #1168/#11
72
Selection of
temperature control
object
characteristics * 11
Default value
:
0
0:Slow heating object
1:Slow heating object
R/W Y
#1173/#11
77
#1174/#11
78
#1175/#11
79
#1176/#11
80
PID algorithm
selection
Default value
:
1
0:Fuzzy PID algorithm
1:Intelligent PID
algorithm
R/W Y
#1181/#11
85
#1182/#11
86
#1183/#11
87
#1184/#11
88
PID output upper
limit setting
Default value
:
0.0%
Setting
range:0.0%~100.0%
R/W Y
#1189/#11
93
#1190/#11
94
#1191/#11
95
#1192/#19
6
PID output lower
limit setting
Default value
:
0.0%
Setting
range:0.0%~100.0%
R/W Y
#1197/#12
01
#1198/#12
02
#1199/#12
03
#1200/#12
04
PID output dead
zone
Default value
:
0.0%
Setting
range:0.0%~100.0%
R/W Y
#1205/#12
09
#1206/#12
10
#1207/#12
11
#1208/#12
12
Manual / automatic
bumpless switching
setting * 12
Default value
:
0
0:Turn off bumpless
switching
1:Turn on bumpless
switching
R/W Y
* 1. #901 ~ #908: input type selection. Select the input type and temperature mode of each channel, #901
corresponds to channel 1, #902 corresponds to channel 2, and so on. When the channel is set to 0, the
channel is closed and the corresponding channel does not perform A/D conversion. The meaning of the
pattern is shown in table 1-10.
Table1-10 Model specification
NO.
value
(decimal)
Significance
1
1
K-type thermocouple input range:
-
100.0
~
200.0
℃
2
2
K-type thermocouple input range
:-
100.0
~
400.0
℃
3
3
K-type thermocouple input range
:-
100.0
~
1200.0
℃
4
4
K-type thermocouple input range
:-
148.0
~
800.0
℉
5
5
K-type thermocouple input range
:-
148.0
~
2192.0
℉
6
6
J-type thermocouple input range
:-
100.0
~
200.0
℃
7
7
J-type thermocouple input range
:-
100.0
~
400.0
℃
8
8
J-type thermocouple input range
:-
100.0
~
600.0
℃
9
9
J-type thermocouple input range
:-
148.0
~
752.0
℉
10
10
J-type thermocouple input range
:-
148.0
~
1112.0
℉
11
11
E-type thermocouple input range
:-
100.0
~
200.0
℃
12
12
E-type thermocouple input range
:
0.0
~
850.0
℃
13
13
E-type thermocouple input range
:-
148.0
~
1562.0
℉
14
14
N-type thermocouple input range
:-
100.0
~
1200.0
℃
15
15
N-type thermocouple input range
:-
148.0
~
2192.0
℉
16
16
T-type thermocouple input range
:-
200.0
~
200.0
℃
17
17
T-type thermocouple input range
:-
200.0
~
300.0
℃
18
18
T-type thermocouple input range
:
0.0
~
300.0
℃
19
19
T-type thermocouple input range
:-
328.0
~
400.0
℉
20
20
T-type thermocouple input range
:-
328.0
~
572.0
℉
21
21
T-type thermocouple input range
:
0.0
~
572.0
℉
22
22
R-type thermocouple input range
:
0.0
~
1600.0
℃
23
23
R-type thermocouple input range
:
32.0
~
2912.0
℉
24
24
S-type thermocouple input range
:
0.0
~
1600.0
℃
25
25
S-type thermocouple input range
:
32.0
~
2912.0
℉
26
26
Pt100
,
input range
:-
50.0
~
150.0
℃