M
AVTMTTR20 Rev 4 Dec 2015
22
Test in Progress Screen
Figure 4-13 shows the TEST IN PROGRESS screen.
Figure 4-13 Test in Progress Screen
If during testing an abnormal condition is detected, one of the error messages
listed in the ERROR MESSAGES section is displayed on the screen.
In case of emergency, press the red button on keypad. It will turn TTR20 OFF.
After emergency situation is gone, turn power ON (green button) to start TTR20
operation.
Test Result Screen
At the completion of the test, the TEST RESULTS screen (Figure 4-14) appears.
Figure 4-14 TTR20 Test Result Screen
The TEST RESULTS screen displays the test voltage used for the test, the
measured turns ratio, the tested winding polarity (“+” for in phase or normal
polarity, and ”-“ for out of phase or reversed polarity), and the tested winding
excitation current.
From this screen, the test results may be printed out on the optional printer
connected to RS232/PRINTER port of the TTR20.
To repeat the test or to start a new one, press the
◊
button on a keypad.
TEST RESULTS
TEST VOLTAGE: 1.5 V
TURNS RATIO: +12.735
EXC. CURRENT: 34 µA
PRINT:“
“ DATA
▼
HEADER
“
◊
“ FOR NEW TEST
TEST IN PROGRESS…
PRESS RED BUTTON FOR
EMERGENCY SHUTDOWN