www.megger.com
AVO®830 and AVO®835
25
Measurements
•
All high-voltage capacitors are discharged
Note:
If a live circuit is detected the instrument will sound a pulsed audible beep and
V OL
(flashing) shows on
the display.
2. Set-up the instrument as shown in Fig 6.
•
Set the Function Dial to
•
Red test lead: V terminal
•
Black test lead: COM terminal
Once the test probes are connected to the capacitor the capacitance is shown on the Primary display.
Note:
This can take a few seconds on large capacitance.
Smart Capacitance
Patent applied for.
When the test leads are connected to a capacitor, which has a residual charge, the live circuit is enabled.
The Smart Capacitance function monitors the charge status of the capacitor, when the charge status reaches a
safe level the instrument will then do a capacitance measurement.