Measurements
Current Measurement
Caution:
To avoid possible damage to the instrument or to the equipment under test:
Check the instrument’s fuses before a current is measured
Use the correct terminals, function, and range for all measurements
Never place the test probes across (in parallel with) any circuit or component when the test probes
are plugged into the current terminals
Note:
To produce a positive reading connect the
black
test probe to the negative side of the circuit and connect
the
red
test probe to the positive side of the circuit. If the test probes are reversed it will produce a negative
reading, but will not damage the instrument.
AC current measurement is selected by default. Press
MODE
to toggle through AC or DC measurements.
Ampere Measurement
Warning: To avoid possible electric shock or personal injury never attempt an in-circuit current
measurement, where the open-circuit potential to earth is greater than 1000 V. You may damage the
instrument or be injured if the fuse blows during such a measurement.
Hz
CAT III 1000V
CAT IV 600V
COM
FUSED
100mA
V
10A
Ω
AVO835
RANGE
MODE
MIN MAX
AVG
REL %
REL
Low Z
HOLD/Auto
ac+dc
APO
Lo
Hz
Hz
°F
Hz
V
Hi
A
mA
OFF
OFF
Ω
°C
A
MODE
A
A
A
Hz
Fig 12: ≤ 10 A Measurement Set-up
Содержание AVO 830
Страница 1: ...AVO 830 and AVO 835 True RMS Digital Multi Meter User Guide ...
Страница 2: ......
Страница 44: ...www megger com AVO 830 and AVO 835 44 ...
Страница 45: ...www megger com AVO 830 and AVO 835 45 ...
Страница 46: ...www megger com AVO 830 and AVO 835 46 ...
Страница 47: ...www megger com AVO 830 and AVO 835 47 ...