manualshive.com logo in svg
background image

OWNER’S MANUAL

Model M4B 

 

Frame Mounted Centrifugal Pump
Hydraulic Coupling Drive

© 2012 

BE1015-MEGA (08/13/12)

700 Osunda Rd. N.E., Albuquerque, NM  87113
Phone: 800-345-8889
www.MegaCorpInc.com

Important

For best possible performance and continuous, satisfactory operation, 
read these instructions before installing your new pump.
Should service be required, this manual can be a valuable guide.  
It should be kept near the installation for ready reference.

CORP.

®

Содержание M4B

Страница 1: ...E Albuquerque NM 87113 Phone 800 345 8889 www MegaCorpInc com Important For best possible performance and continuous satisfactory operation read these instructions before installing your new pump Shou...

Страница 2: ...rts Breakdown 6 7 Start up General Information 8 9 Maintenance Routine Inspection 10 General Information 11 Packing Ring Replacement 12 Shaft Sleeve Installation Replacement 13 Impeller Replacement 14...

Страница 3: ...alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury warns about hazards that will cause s...

Страница 4: ...g box packing Fill the stuffing box with a crusting grease Rust Ban 326 or equal then pack the end of the stuffing box with rolled vapor phase inhibitor paper and seal with weatherproof tape Dry pump...

Страница 5: ...mp plate is normally on the bearing bracket Information found on this plate is shown below To ensure correct parts are received provide all nameplate data when ordering The B M Bill of Material number...

Страница 6: ...screw Lock External Tooth Washer Casing Wear Ring Casing O Ring Impeller Wear Ring Seal Plate Frame Mount Bracket Grease Fitting Hex Capscrew Pipe Plug Stud Hex Nut Shaft Sleeve Bearing Cap Motor Brac...

Страница 7: ...r Ring Casing O Ring Impeller Wear Ring Seal Plate Frame Mount Bracket Grease Fitting Hex Capscrew Pipe Plug Oil Seal Hex Capscrew Shaft Sleeve Pipe Plug Roller Bearing Shaft Bearing Cap Motor Bracket...

Страница 8: ...riming is the displacement of air with water in the pump and suction piping Pump MUST BE completely filled with water when operating HYDRAULIC BALANCED PUMPS Hydraulic balanced pumps operate with a ve...

Страница 9: ...area and gland are not hot If heating is detected loosen the gland nuts evenly until water is just running out of stuffing box in a DROPLET form approximately 40 60 drops per minute Water must not be...

Страница 10: ...t all system piping connections for leakage or possible misalignment Complete any lubrication requirements as dictated by pump and driver owner s manual Inspect packing or mechanical seal for possible...

Страница 11: ...ur pump and reduce down time Check your model style against parts breakdown See FIGURES 1 and 2 when selecting spares Mechanical Shaft Seal Packing Set and Packing Hooks Shaft Sleeve s All O Rings Req...

Страница 12: ...cing over shaft sleeve and pushing them in as far as they will go Rotate ring joint 90 degrees when installing each ring Slide packing gland into position gland must enter stuffing box bore then gentl...

Страница 13: ...ew sleeve onto the shaft Rotate the sleeve at least twice before butting it against the shaft shoulder Wipe any excess adhesive off the shaft and sleeve NOTE With activator the adhesive will begin to...

Страница 14: ...place the casing wear ring Check the clearance between the impeller hub wear ring and seal plate wear ring If it is more than 020 0 5 mm on a side replace the seal plate wear ring IMPELLER INSTALLATIO...

Страница 15: ...to place See FIGURE 6 Do not damage the seal face 10 Reinstall the seal plate Hold in place with 2 capscrews Cover all shaft threads with the seal installation bull nose tool to protect the seal durin...

Страница 16: ...als in the bearing bracket and bearing cap Lubricate with oil Pack bearings with a lithium based NLGI No 2 extra pressure ball bearing grease Force enough grease into each bearing to fill internal spa...

Страница 17: ...ot properly adjusted Adjust gland III SYSTEM A Pressure required by system at design Compare pump pressure and flow rate against pump characteristic curve flow rate exceeds pressure rating of pump Che...

Страница 18: ...Page 18 F00637...

Страница 19: ...F00637 Page 19...

Страница 20: ......

Отзывы: