background image

TECHNICAL DATA

MODEL: HLR

3 of 11  

Dimensions

HLR240

HLR360

A

1050 mm

1290 mm

B

952 mm

1192 mm

C

710 mm

830 mm

D

242 mm

362m/m

 

TECHNICAL DATA

HLR

240-1.3

360-1.3

Power supply

230 V 50HZ

Motor power rating

276 W

Absorbed consumption

1.3 A

Capacitor

12 uf

Maximum pressure

50 bar

Rod stroke length

242 mm

362 mm

Closing manoeuvre time

20 s

31 s

Opening manoeuvre time

17 s

26 s

Closing force

637 Kg

Opening force

508 Kg

Maximum gate length

4 m

6 m

Temperature range

-15 to 80 °C

Thermal protection

100 °C

Group weight

11 Kg

12 Kg

 

FEATURES

HLR

SB

BAC BACN

ANTI-CRUSHING

 

 

HYDRAULIC CLOSURE OUTPUT

 

LOCK IN BOTH MANOEUVRES

 

LOCK AT CLOSURE

 

LOCK AT OPENING

 

REVERSIBILITY IN BOTH MANOEUVRES

WINDPROOF REGULATION

 

SOFT STOP AT CLOSURE

SOFT STOP AT OPENING

Содержание HLR240 BAC-1.3

Страница 1: ...INSTRUCTION MANUAL AUTOMATIC GATE MECHANISM HLR240 BAC 1 3 HLR360 BAC 1 3 Ed2 27 08 18...

Страница 2: ...r of which it will be a component has been identified and declared to comply with the terms of Directive 2006 42 EEC and subsequent amendments We put the CE conformity marking on the machine Plate num...

Страница 3: ...s install a differential with a value of 0 03 A and a thermomagnetic switch with an opening of the contacts of at least 3 mm provided with overload and short circuit protection Connect the yellow gree...

Страница 4: ...50 bar Rod stroke length 242 mm 362 mm Closing manoeuvre time 20 s 31 s Opening manoeuvre time 17 s 26 s Closing force 637 Kg Opening force 508 Kg Maximum gate length 4 m 6 m Temperature range 15 to 8...

Страница 5: ...ning and closing Ti time between complete manoeuvres opening closing Graph 1 Note To ensure the full closing and opening of the gate it is necessary to increase the manoeuvring times by 5 sec onds The...

Страница 6: ...800KG HLR 240 110 HLR 360 115 HLR OPENING INWARDS Fig 2 M A B C 85 195 185 90 90 180 180 90 95 165 180 90 100 150 180 90 105 140 180 90 110 125 180 90 115 115 180 90 120 105 180 90 OPENING OUTWARDS Fi...

Страница 7: ...vertical line as possible Dimension C remain constant in both motors model 360 C 90 mm and model 240 C 70 mm Example What would be the dimension A and what engine should I use to automate a gate with...

Страница 8: ...ASSEMBLY INSTRUCTIONS 7 of 11 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...

Страница 9: ...tion move the ring at the end of the stroke on the rod Fig 9 page 7 to the telescopic bushing Fig 10 page 7 and attach it with the allen screw Now we can activate the motor electrically Reposition the...

Страница 10: ...e RED BLUE View of the motor from below LOCKING OPERATION The BAC system incorporated in the HLR device offers a wide variety of possibilities Here is how it should be manipulated to get the most out...

Страница 11: ...h and it is not an obstacle that must be released In order to be able to do without a limit switch when opening it is necessary for the panel to have the option that when the gate is opening and finds...

Страница 12: ...Kit and Gate supp 240 A232 11001 K1 Pillar supp Kit and Gate supp 360 A232 11002 K1 21 Hydraulic lock A232 21002 00 22 Hydraulic hose in metres 80736 23 Hose assembly kit A232 22003 K1 No NAME Ref 1...

Отзывы: