22
Maintenance and Field Adjustment
Impeller Removal
In the case that there is buildup below the
impeller that cannot be reached, the impeller
assembly can easily be removed.
Impeller Removal
TOOLS RECOMMENDED:
Elbow High Rubber Gloves
STEP 1: With SolarBee machine off and PV
module gate open, locate the clevis pin going
through the upper shaft coupling. Remove the
hair pin and pull clevis pin out.
STEP 2: Grab the impeller shaft below the flag
indicator, lift up and then outward until lower
coupling and shaft are disconnected from
upper coupling and brushless motor.
STEP 3: Observe and clean any debris located
on the bottom of the impeller.
STEP 4: Observe and clean any debris located
down in the dish where the impeller rests.
STEP 5: Once clean, place impeller assembly
back in place (Slide lower coupling into upper
coupling and allow to drop down into place).
Be sure bottom of impeller shaft fits into the
bushing in the dish and that the coupling sleeve
is in place inside the shaft coupling assembly.
STEP 6: Place clevis pin back through upper
shaft coupling and secure with hair pin.
STEP 7: Close PV module gate and turn
SolarBee machine back on.
Bushing
Coupling Sleeve
Lower Coupling
Upper Coupling
Hair Pin
Clevis Pin
Shaft Coupling
Impeller Assembly Removed
Impeller Assembly Removal Motion
Содержание SolarBee SB10000DM