background image

13

Manufacturer’s declaration – electromagnetic immunity

The 

Comfort Glide Air Blower

 is intended for use in the electromagnetic environment 

(for professional healthcare) specified below. The customer or the user of the 

Comfort Glide Air Blower

 should assure that it is used in such an environment.

Immunity 

test

IEC 60601 test level

Compliance level

Electromagnetic environment-guidance

(for professional healthcare environment)

Conducted 

RF

IEC 61000-

4-6

Radiated 

RF

IEC 61000-

4-3

3 Vrms:

0,15 MHz – 80 MHz

6 Vrms: 

in ISM bands between

0,15 MHz and 80 MHz
80 % AM at 1 kHz

3 V/m

80 MHz – 2,7 GHz

80 % AM at 1 kHz

3 Vrms:

0,15 MHz – 80 MHz

6 Vrms: 

in ISM bands between

0,15 MHz and 80 MHz
80 % AM at 1 kHz
3 V/m

80 MHz – 2,7 GHz 

80 % AM at 1 kHz

Portable and mobile RF communications 

equipment should be used no closer to 

any part of the

 Comfort Glide Air Blower 

including cables, than the recommended 

separation distance calculated from the 

equation applicable to the frequency of the 

transmitter.

Recommended separation distance:

d = 1,2 

d = 1,2         80 MHz to 800 MHz 

d = 2,3         800 MHz to 2,7 GHz 
Where P is the maximum output power    

rating of the transmitter in watts (W)           

according to the transmitter manufacturer 

and d is the recommended separation 

distance in metres (m).
Interference may occur in the vicinity of 

equipment marked with the following 

symbol:

NOTE 1:

  At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2:

 These guidelines may not apply in all situations. Electromagnetic propagation is affected by 

absorption and reflection from structures, objects and people.

WASTE DISPOSAL

This Product has been supplied from an environmentally 

aware manufacturer that complies with the Waste Electrical 

and Electronic Equipment Directive (WEEE). 

This product may contain substances that could be harmful 

to the environment if disposed of in places (landfills) that are 

not appropriate according local regulations. Please be  

environmentally responsible and recycle this product through 

your recycling facility at its end of life.

Содержание ComfortGlide

Страница 1: ...USER MANUAL MSC60090 BLOWER Comfort Air GLIDE...

Страница 2: ...se 4 General safety 4 Device Feature 4 Inflating Comfort Glide Air Sheet 5 Maintenance Troubleshooting 6 Cleaning Disinfection Protocol 7 General Disassembly of Parts 7 Specification 9 Electromagnetic...

Страница 3: ...Blower Precaution Comfort Glide Air Blower To reduce the risk of burns electrocution fire or injury to persons 1 Use this product only for its intended use as described in this manual Do not use attac...

Страница 4: ...ans safely reposition and move patients The system has been designed to reduce risks and make patient repositioning and transfers easier and safer GENERAL SAFETY It is important to read the informatio...

Страница 5: ...will permit free movement of the hose CAUTION It is important to routinely inspect power cable to ensure it is not obstructed or causing a tripping hazard Check the power cable is not under strain or...

Страница 6: ...wer cord plug is securely connected and fits snugly into the outlet Secure plug connection and turn on Air Blower power switch Blown fuses in pump and plug Check for blown fuses in pump and plug Repla...

Страница 7: ...cility s guidelines for cleaning and disinfecting the Comfort Glide Air Blower Ensure that the power unit is off 2 Unplug the power cord from the wall outlet 3 Examine the surface of the Air Blower fo...

Страница 8: ...8 2 Changing filter a Unscrew 3 screws on the bottom cover b Open the filter cover and identify the filter c Replace the filter and assemble the parts in reverse order...

Страница 9: ...ng or collocating equipment and when routing cables and accessories WARNING RF mobile communications equipment can effect medical electrical equipment Model Name Comfort Glide Air Blower Size in CM L...

Страница 10: ...fort Glide Air Blower as rec ommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency...

Страница 11: ...s used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance for professional healthcare environment Electrostatic discharge ESD IEC 61000 4 2...

Страница 12: ...400 Pulse modulation b 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FM c 5 kHz deviation 1 kHz sine 2 0 3 28 28 710 704 787 LTE Band 13 17 Pulse modulation b 217 Hz 0 2 0 3 9 9 745 780 810 800 96...

Страница 13: ...calculated from the equation applicable to the frequency ofthe transmitter Recommendedseparationdistance d 1 2 d 1 2 80 MHz to 800 MHz d 2 3 800 MHz to 2 7 GHz Where P is the maximum output power rati...

Страница 14: ...transported another location Temperature limitations 5 o C to 60 o C 41 o F to 140 o F Relative Humidity 30 90 SYMBOLS USED Type B Applied part Refer to Instruction Manual Booklet Keep dry Waste Dispo...

Страница 15: ...at no charge This warranty excludes equipment damaged through shipping tampering improper maintenance carelessness accidents negligence misuse or which has been altered repaired or dismantled other th...

Страница 16: ...rademarks of Medline Industries Inc Made in Taiwan for Medline Industries Inc Three Lakes Drive Northfield IL 60093 USA RC19CMT Medline Industries Inc Three Lakes Drive Northfield IL 60093 USA Medline...

Отзывы: