Air & Surface Steriliser System
INSTALLATION & OPERATING MANUAL REVISION: 04/2020 | page 7 of 16
Chapter 7. UV-C LAMP and BATTERY
7.1 IMPORTANT ADVICE
•
Do not touch the anodized aluminium air diffuser plates.
•
Do not touch the quartz part of the UV lamp. Handle the UV lamp by the cap and end terminal only.
•
Any dirt on the quartz part of the lamp can be cleaned with a dry cloth.
•
After approximately 8000 hours or 12 months of continuous burning, the UV-C lamp will lose 20% to 30% of
its power and must be replaced.
•
The lamps and battery must be replaced every 12 months to ensure optimum performance of the system.
•
If the indicator light (shown in Chapter 4 as part P in the diagram) is flashing and an audible alarm is heard it
is time for the lamp and battery to be replaced.
7.2 LAMP AND BATTERY REPLACEMENT/INSTALLATION
7.2.1 Disconnect from power. Unscrew 2x front
cover captive screws and detach cover.
7.2.2 If you are removing an OLD lamp, firmly grip
lamp terminal/connector end (or end cap)
and carefully slide lamp out of the socket.
Carefully lift lamp away from the spring clip
and socket.
If you are fitting a NEW lamp, firmly grip lamp terminal/connector end (or end cap) and carefully slide
lamp into the socket and spring clip.
7.2.3 Remove OLD battery and/or fit NEW battery as shown.
7.2.4 Replace the front cover using the 2x captive screws. Reconnect the power to the unit.