background image

Air & Surface Steriliser System

REVISION: 04/2020  |  page 10 of 16                                                                                        INSTALLATION & OPERATING MANUAL

 

Chapter 9.   OPERATING INSTRUCTIONS 

9.1   GENERAL ADVICE and TROUBLESHOOTING 

The following are general guidelines for the operator of the unit. If any questions arise, please do not hesitate to 

contact Mechline or your Mechline dealer.  

9.1.1  Unit not operating at all 

 

Ensure that the power supply is connected and working  

 

Check unit power plug connections 

 

Try alternative lamp 

9.1.2  Excessive metallic/electrical odour from HyGenikx unit 

 

This is harmless and quite normal during the first few days of installation  

 

If odour continues check lamp is clean - this can be wiped with an alcohol based cleaner  

 

Change for lower output lamp 

9.1.3  Unit is working correctly but the room odour remains! 

 

Check that the unit is the right type and strength for the area. Contact Mechline if you are unsure 

 

Replace/upgrade lamp 

 

If unit previously worked well, clean thoroughly following the manufacturer’s instructions 

 

Refer to Section 9.2 Checklist if Room Odour Remains 

9.2   CHECKLIST IF ROOM ODOUR REMAINS (washrooms, refuse, etc.) 

9.2.1  Check the unit is correctly sized for the room area 

Measure length x width of room to give m

2

 

9.2.2  Confirm electrical supply is continuous and not being switched off in error 

Some locations such as shopping centres have a central switch off 

9.2.3  Check the unit location 

 

At a minimum height of 1.8 metres – units must be wall mounted vertically  

 

Keep in mind sources of strong airflow which may disrupt the unit distribution  

 

Refer to Chapter 5 Location Advice 

9.2.4  Washroom specific points 

 

Confirm the individual cistern/water management system to each urinal is flushing correctly 

 

Ensure traps are clean, draining correctly and water seals are intact 

 

Rectify any leaks, key areas to check are behind melamine panels and connections between earthenware 

pipes from plastic urinal waste 

 

With Stainless steel urinals check for calcium build-up, bacteria levels can be higher than normal with 

these urinals so consider upgrading lamp  

 

Check floor below urinals is not porous and that grouting has not broken down 

 

Check that there are no missing seals around drain or manhole covers 

9.2.5  General points 

 

Can the output air from the unit access the odour? Check and rectify any possible source of the bad odour 

that could be trapped behind panels or subfloors (i.e. unsealed concrete floors). 

 

Is strong external airflow preventing air from the unit distributing correctly 

 

Is the odour source wet - leaks must be completely dried out in order to eradicate odours 

 

Is the odour extreme and ongoing – may need to increase unit output 

 

Confirm standard cleaning practices are in place 

Содержание HyGenikx+ HGX-T-05-O

Страница 1: ...is an advanced and compact wall mounted steriliser system proven to eradicate viruses and bacteria throughout foodservice and hospitality environments washrooms changing rooms and beyond Utilising a c...

Страница 2: ...eces Noise level 1 metre 39dB Air flow rate 20 m3 hr Suggested coverage 10 30 m2 10 40 m2 Installation Wall mount Housing material Aluminium alloy internal polycarbonate front ABS base Colour Front Wh...

Страница 3: ...ness of breath these symptoms should only be short term and be resolved when the individual is removed to fresh air If there are any concerns about the ozone produced please disconnect power to the un...

Страница 4: ...s section 3 2 5 Before attempting servicing or maintenance tasks the unit MUST be isolated from the power source and disconnected 3 2 6 Should a fault occur with the unit immediately isolate and disco...

Страница 5: ...d H On Off indicator light Chapter 5 LOCATION ADVICE For general advice refer to Section 9 4 11 The unit should be placed in a ventilated area Some initial odour caused by the electrical components wi...

Страница 6: ...k and drill holes using template provided on packing box 6 1 4 Insert wall plugs into drilled holes Use hammer to fit wall plugs into position Insert screws provided into wall plugs and screw into pos...

Страница 7: ...nce of the system If the indicator light shown in Chapter 4 as part P in the diagram is flashing and an audible alarm is heard it is time for the lamp and battery to be replaced 7 2 LAMP AND BATTERY R...

Страница 8: ...ch unit Is the indicator illuminated on unit front with lamp light also visible through the vents of unit If not please refer to Section 9 3 Lamp Unit Failure Checklist Is there an odour present in th...

Страница 9: ...and BATTERY for 30m 2 GENERAL areas HGX 10 F LAMP ORANGE with food safe shatterproof sheath BATTERY for 10m 2 FOOD SERVICE areas HGX 20 F LAMP BLUE with food safe shatterproof sheath BATTERY for 20m 2...

Страница 10: ...ontinuous and not being switched off in error Some locations such as shopping centres have a central switch off 9 2 3 Check the unit location At a minimum height of 1 8 metres units must be wall mount...

Страница 11: ...moisture source Increase ventilation of environment Consider switching to a fan powered unit E mail Mechline for further advice 9 3 5 Lamp not pushed fully home can cause short circuits Check and conn...

Страница 12: ...use it is not unusual for the unit to produce a slightly metallic odour this is caused by the lamp bedding in This should dissipate within 48 hours 9 4 4 In addition to odours what are the microorgani...

Страница 13: ...eak down Volatile Organic Compounds VOCs Interaction of the Dual waveband UV with the TiO2 heterogeneous catalyst both creates and breaks down Oxygen molecules transforming Oxygen into a highly reacti...

Страница 14: ...circulation installing the unit as close as is practical to the strong odour or contamination source is recommended i e next to food storage in cold store above preparation areas in kitchen next to u...

Страница 15: ...amp and the anodized aluminium air diffuser plates at all These plates are self cleaning Chapter 11 AFTER SALES and SERVICE SUPPORT For technical assistance please contact Mechline technical mechline...

Страница 16: ...sociates Material and information included are correct at time of print Intending buyers and users must satisfy themselves as to the suitability and safety of the products for their particular purpose...

Отзывы:

Похожие инструкции для HyGenikx+ HGX-T-05-O