9.4   QUESTIONS and ANSWERS 

The following are general guidelines for the operator of the unit. If any questions arise, please do not hesitate to contact 

Mechline or your Mechline dealer.  

9.4.1  How do I know the HyGenikx unit is working? 

Firstly, the green cross light indicator will be illuminated on the front of the unit to show the product is operating. 

After 12 months of use the built-in warning system will tell you when the lamp (and battery) requires 

replacement to ensure peak efficiency. 

 

There will be a definite change in the environmental air quality. Internal environments that have a usual lingering 

background odour, whether from cooking/food, body odour, cleaning products, waste material, or a combination 

of these, will smell noticeably fresher. This change will be most obvious at the start of a working day, clearly 

demonstrating the unit is working. 

 

Areas where it is easier to monitor performance are those with obvious odour issues, such as a washroom, 

changing room or bin store. Here, odours will be significantly reduced or eliminated completely.  

9.4.2  How are your products different to fragrance units? 

(General) They go far beyond odour control. Rather than masking odours they remove smells by targeting and 

killing the root cause, which is usually microorganisms. (Food) In food storage microorganisms are responsible for 

spoilage and the shortening of food life. Independent testing has demonstrated how we extend food life 

(specifically vegetables and soft fruits) by reducing the microorganisms. Note: This unit is not to replace product 

“use by” date.

 

9.4.3  What do they smell like? Is there a fragrance? 

The absence of unpleasant background odours is usually the first thing customers notice. The 'smell' is described 

as "clean and fresh" and has often been likened to mountain air. No masking fragrances are used. Note: Within 

the first 48 hours of use it is not unusual for the unit to produce a slightly metallic odour, this is caused by the lamp 

bedding in. This should dissipate within 48 hours. 

9.4.4  In addition to odours, what are the microorganisms that are reduced by this technology? 

Bacteria, Viruses, Mould, Fungi. Multiple independent tests demonstrate the efficacy against the most prevalent 

of these including Listeria, E coli, Staphylococcus aureus, Staphylococcus epidermis, Aspergillus fumigatus, MS-2 

Coliphage, MRSA and Clostridium difficile. 

9.4.5  Does air need to pass through a unit to be sanitised? 

No, our technology uses both internal and external processes so although contaminates passing through the unit 

will be sanitised, it also produces cleaning air which circulates throughout. This is why HyGenikx can cover such a 

large area.  

9.4.6  Will units reduce bacteria on walls and surfaces or just in the air? 

Cleaning air from the unit will target and reduce all contamination wherever the ‘clean’ air can reach. Test results 

show substantial reduction in both air and surface contamination in relatively short periods of time. 

9.4.7  How would you explain your technology in simple terms? 

The specialist Germicidal UV lamp combined with Titanium Dioxide catalyst cleaning plates eliminate any odours 

and harmful microorganisms drawn into the unit. The lamp also produces a purifying plasma (Plasma Quatro), 

which convects from the unit and circulates around the room sanitising the air and surfaces. Part of the process 

also has an ionising effect, which will reduce the amount of airborne dust and debris.  

9.4.8  Can you explain your technology in more depth? 

HyGenikx units are fitted with powerful dual waveband Ultraviolet lamps. A high-intensity broad spectrum 

ultraviolet lamp, with UVC 254 nm germicidal light wavelengths is the first part of photocatalytic air purification 

technology. A wider set of ultraviolet wavelength 185 nm are employed for catalyst activation. Although UV light 

alone will degrade toxic organic compounds, reaction rates are much faster with photocatalytic assistance. 

 

The catalyst material in the HyGenikx [photocatalytic purifier] is Titanium Dioxide, TiO2. 

 

Содержание HyGenikx+ HGX-T-05-O

Страница 1: ...is an advanced and compact wall mounted steriliser system proven to eradicate viruses and bacteria throughout foodservice and hospitality environments washrooms changing rooms and beyond Utilising a c...

Страница 2: ...eces Noise level 1 metre 39dB Air flow rate 20 m3 hr Suggested coverage 10 30 m2 10 40 m2 Installation Wall mount Housing material Aluminium alloy internal polycarbonate front ABS base Colour Front Wh...

Страница 3: ...ness of breath these symptoms should only be short term and be resolved when the individual is removed to fresh air If there are any concerns about the ozone produced please disconnect power to the un...

Страница 4: ...s section 3 2 5 Before attempting servicing or maintenance tasks the unit MUST be isolated from the power source and disconnected 3 2 6 Should a fault occur with the unit immediately isolate and disco...

Страница 5: ...d H On Off indicator light Chapter 5 LOCATION ADVICE For general advice refer to Section 9 4 11 The unit should be placed in a ventilated area Some initial odour caused by the electrical components wi...

Страница 6: ...k and drill holes using template provided on packing box 6 1 4 Insert wall plugs into drilled holes Use hammer to fit wall plugs into position Insert screws provided into wall plugs and screw into pos...

Страница 7: ...nce of the system If the indicator light shown in Chapter 4 as part P in the diagram is flashing and an audible alarm is heard it is time for the lamp and battery to be replaced 7 2 LAMP AND BATTERY R...

Страница 8: ...ch unit Is the indicator illuminated on unit front with lamp light also visible through the vents of unit If not please refer to Section 9 3 Lamp Unit Failure Checklist Is there an odour present in th...

Страница 9: ...and BATTERY for 30m 2 GENERAL areas HGX 10 F LAMP ORANGE with food safe shatterproof sheath BATTERY for 10m 2 FOOD SERVICE areas HGX 20 F LAMP BLUE with food safe shatterproof sheath BATTERY for 20m 2...

Страница 10: ...ontinuous and not being switched off in error Some locations such as shopping centres have a central switch off 9 2 3 Check the unit location At a minimum height of 1 8 metres units must be wall mount...

Страница 11: ...moisture source Increase ventilation of environment Consider switching to a fan powered unit E mail Mechline for further advice 9 3 5 Lamp not pushed fully home can cause short circuits Check and conn...

Страница 12: ...use it is not unusual for the unit to produce a slightly metallic odour this is caused by the lamp bedding in This should dissipate within 48 hours 9 4 4 In addition to odours what are the microorgani...

Страница 13: ...eak down Volatile Organic Compounds VOCs Interaction of the Dual waveband UV with the TiO2 heterogeneous catalyst both creates and breaks down Oxygen molecules transforming Oxygen into a highly reacti...

Страница 14: ...circulation installing the unit as close as is practical to the strong odour or contamination source is recommended i e next to food storage in cold store above preparation areas in kitchen next to u...

Страница 15: ...amp and the anodized aluminium air diffuser plates at all These plates are self cleaning Chapter 11 AFTER SALES and SERVICE SUPPORT For technical assistance please contact Mechline technical mechline...

Страница 16: ...sociates Material and information included are correct at time of print Intending buyers and users must satisfy themselves as to the suitability and safety of the products for their particular purpose...

Отзывы: