9.3   LAMP/UNIT FAILURE CHECKLIST 

9.3.1  Unit wired to shared spur (i.e. hand dryer) can mean power surges causing lamp failure 

This is incorrect, the unit requires a dedicated spur 

9.3.2  Intermittent power supply or power switched off at night can shorten lamp life 

Relocate unit or unit will require additional lamp changes 

9.3.3  Debris blocking air intakes can reduce airflow causing lamps, or electrical ballasts to overheat 

 

Reduce period between unit cleans to prevent re-occurrence 

9.3.4  Unit fitted in a high moisture environment or directly above a water source such as urinals can lead to 

water vapour ingress 

 

Re-site away from moisture source 

 

Increase ventilation of environment  

 

Consider switching to a fan-powered unit. E-mail Mechline for further advice* 

9.3.5  Lamp not pushed fully home can cause short circuits  

 

Check and connect lamp correctly. Refer to Chapter 7 Lamp and Battery 

9.3.6  Touching the glass of lamps with bare fingers can shorten lamp life 

 

Use gloves or tissue when changing lamps 

 

If touched in error, clean glass with alcohol based cleaner 

 

When fitting lamp please refer to Chapter 7 Lamp and Battery 

9.3.7  Loose connection in power supply to unit or internal wiring 

 

Check all visible connections 

 

If problems persist the unit may need to be returned to Mechline for inspection* 

9.3.8  Unidentified fault, suspected part failure 

 

Check lamp, for other parts return to Mechline for inspection* 

 

*For technical assistance e-mail [email protected], quoting the HyGenikx model number. The model number 

can be found on both sides of the unit.

 

 

Содержание HyGenikx+ HGX-T-05-O

Страница 1: ...is an advanced and compact wall mounted steriliser system proven to eradicate viruses and bacteria throughout foodservice and hospitality environments washrooms changing rooms and beyond Utilising a c...

Страница 2: ...eces Noise level 1 metre 39dB Air flow rate 20 m3 hr Suggested coverage 10 30 m2 10 40 m2 Installation Wall mount Housing material Aluminium alloy internal polycarbonate front ABS base Colour Front Wh...

Страница 3: ...ness of breath these symptoms should only be short term and be resolved when the individual is removed to fresh air If there are any concerns about the ozone produced please disconnect power to the un...

Страница 4: ...s section 3 2 5 Before attempting servicing or maintenance tasks the unit MUST be isolated from the power source and disconnected 3 2 6 Should a fault occur with the unit immediately isolate and disco...

Страница 5: ...d H On Off indicator light Chapter 5 LOCATION ADVICE For general advice refer to Section 9 4 11 The unit should be placed in a ventilated area Some initial odour caused by the electrical components wi...

Страница 6: ...k and drill holes using template provided on packing box 6 1 4 Insert wall plugs into drilled holes Use hammer to fit wall plugs into position Insert screws provided into wall plugs and screw into pos...

Страница 7: ...nce of the system If the indicator light shown in Chapter 4 as part P in the diagram is flashing and an audible alarm is heard it is time for the lamp and battery to be replaced 7 2 LAMP AND BATTERY R...

Страница 8: ...ch unit Is the indicator illuminated on unit front with lamp light also visible through the vents of unit If not please refer to Section 9 3 Lamp Unit Failure Checklist Is there an odour present in th...

Страница 9: ...and BATTERY for 30m 2 GENERAL areas HGX 10 F LAMP ORANGE with food safe shatterproof sheath BATTERY for 10m 2 FOOD SERVICE areas HGX 20 F LAMP BLUE with food safe shatterproof sheath BATTERY for 20m 2...

Страница 10: ...ontinuous and not being switched off in error Some locations such as shopping centres have a central switch off 9 2 3 Check the unit location At a minimum height of 1 8 metres units must be wall mount...

Страница 11: ...moisture source Increase ventilation of environment Consider switching to a fan powered unit E mail Mechline for further advice 9 3 5 Lamp not pushed fully home can cause short circuits Check and conn...

Страница 12: ...use it is not unusual for the unit to produce a slightly metallic odour this is caused by the lamp bedding in This should dissipate within 48 hours 9 4 4 In addition to odours what are the microorgani...

Страница 13: ...eak down Volatile Organic Compounds VOCs Interaction of the Dual waveband UV with the TiO2 heterogeneous catalyst both creates and breaks down Oxygen molecules transforming Oxygen into a highly reacti...

Страница 14: ...circulation installing the unit as close as is practical to the strong odour or contamination source is recommended i e next to food storage in cold store above preparation areas in kitchen next to u...

Страница 15: ...amp and the anodized aluminium air diffuser plates at all These plates are self cleaning Chapter 11 AFTER SALES and SERVICE SUPPORT For technical assistance please contact Mechline technical mechline...

Страница 16: ...sociates Material and information included are correct at time of print Intending buyers and users must satisfy themselves as to the suitability and safety of the products for their particular purpose...

Отзывы:

Похожие инструкции для HyGenikx+ HGX-T-05-O