Display Setting 

The LCD display information will be switched in turns by pressing “SCROLL” key. The selectable information is 
switched as below order: input voltage, input frequency, PV voltage, charging current, battery voltage, output 
voltage, output frequency, load percentage, load in Watt, load in VA, load in Watt, DC discharging current, main 

CPU Version and second CPU Version. 
 

Selectable 

information 

LCD display 

Selectable 

information 

LCD display 

Input voltage/Output 
voltage   

(Default Display 
Screen) 

Input Voltage=230V, 

output voltage=230V 

 

Load 

percentage 

Load percent=70%

 

 

Input frequency 

Input frequency=50Hz

 

 

Load in VA 

When  connected  load  is  lower 
than 1kVA, load in VA will present 

xxxVA like below chart. 

 

When  load  is  larger  than  1kVA 
(

1KVA), load in VA will present 

x.xkVA like below chart. 

 

PV voltage 

PV voltage=30V 

 

Load in Watt 

When  load  is  lower  than  1kW, 
load  in  W  will present xxxW  like 

below chart. 

 

When  load  is  larger  than  1kW 

(

1KW),  load  in  W  will  present 

x.xkW like below chart. 

 

Charging current   

(if PV normal) 

Charging current=55A 

 

Main CPU 
version 

checking 

Main CPU version 00001.01 

 

Содержание IVR-1200MPPT

Страница 1: ...USER MANUAL IVR 1200MPPT IVR 2400MPPT Solar Inverter...

Страница 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 5 6 Trouble Shooting 14 7 Specifications 15...

Страница 3: ...wire is not undersized Do not operate the Inverter with damaged or substandard wiring CAUTION To reduce risk of fire hazard do not cover or obstruct the cooling fan CAUTION Do not operate the inverter...

Страница 4: ...screws Connect to Utility and Charge Plug in the AC input cord to the wall outlet The unit will automatically charge the connected external battery even though the unit is off Connect to External Batt...

Страница 5: ...unit Step 5 Take the DC breaker on Connect to Solar Panel CAUTION Before connecting to PV modules please install separately a DC circuit breaker between inverter and PV modules WARNING All wiring must...

Страница 6: ...numbers Maximum PV module numbers in series Total PV module numbers Max Charging power of inverter Pmax of PV module 0 8 MPPT conversion rate Take IVR 1200MPPT inverter as an example to select proper...

Страница 7: ...Audible Alarms There are three indicators in the front panel of the unit LED Indicator Messages Green Solid On Output is available in bypass mode Flashing Output is powered by battery in inverter mode...

Страница 8: ...ne mode In AC mode it will present battery charging status Status Battery voltage LCD Display Constant Current mode Constant Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom...

Страница 9: ...VAC Narrow If selected acceptable AC input voltage range will be within 170 280VAC 02 Battery type AGM Default Flooded User defined 03 Max AC charging current 25A default 10A 04 Bulk charging C V volt...

Страница 10: ...and battery energy will provide power to the loads only when utility power is not available Solar first Solar energy provides power to the loads as first priority If solar energy is not sufficient to...

Страница 11: ...V default 11 8V 12 0V 12 3V 12 5V 12 8V Available options in IVR 2400MPPT model 22 0V 22 5V 23 0V default 23 5V 24 0V 24 5V 25 0V 25 5V 11 Setting voltage point back to battery mode when selecting SBU...

Страница 12: ...attery only when solar energy is not available Solar and utility Solar energy and utility will charge battery at the same time Only Solar Solar energy will be the only charger source no matter utility...

Страница 13: ...lay Input voltage Output voltage Default Display Screen Input Voltage 230V output voltage 230V Load percentage Load percent 70 Input frequency Input frequency 50Hz Load in VA When connected load is lo...

Страница 14: ...r can charge battery with AC bypass output Utility input bypass to output charger available LCD backlight is off Charging by utility and PV energy Charging by utility Charging by PV energy Line Mode T...

Страница 15: ...Icon on Fault Code Fault Event Icon on 00 Output short circuit 05 Fan locked 01 Over load time out 06 Over temperature 03 Output voltage too high 08 Over charge Warning Indicator Warning Code Warning...

Страница 16: ...ge output source priority to Utility first No LED display on the front panel when the utility power is normal No LED display Battery is not connected well Check the external battery cable and terminal...

Страница 17: ...ing Charge Voltage 13 7 VDC 0 5 VDC 27 4 VDC 1 VDC CV Charging Voltage Lead Acid Battery 14 3 VDC 0 5 VDC 28 6 VDC 1 VDC Lithium Battery 14 6 VDC 0 5 VDC 29 2 VDC 1 VDC Cut Off Voltage 10 5 VDC 0 5 VD...