background image

 

1. Introduction 

Thank you for purchasing this solar inverter. This simple solar inverter is designed to power your home 
appliances or precious 3C electronics. It also can handle motor-type loads with high surge power such as 
vacuums, small freezers, or drills. With built-in MPPT solar charger, it can convert solar power to battery power 
and provide continuous power to connected equipment during night time.     
This manual is for qualified personnel. The tasks described in this manual may be performed by qualified 
personnel only. 

 

2. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

Before using the inverter, please read all instructions and cautionary markings on the unit, this 
manual and the batteries. 
 

 

 
 
General Precaution- 
CAUTION!
 The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type. 
CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers. 
Any unqualified batteries may cause damage and injury. Do NOT use old or overdue batteries. Please check the 
battery type and date code before installation to avoid damage and injury. 
CAUTION! Authorized service personnel should reduce the risk of electrical shock by disconnecting AC, DC and 
battery power from the inverter before attempting any maintenance or cleaning or working on any circuits 
connected to the inverter. Turning off controls will not reduce this risk. Internal capacitors can remain charged 
for 5 minutes after disconnecting all sources of power. 
CAUTION! Do not disassemble this inverter yourself. It contains no user-serviceable parts. Attempt to service 
this inverter yourself may cause a risk of electrical shock or fire and will void the warranty from the 
Manufacturer. 
CAUTION! To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that 
the wire is not undersized. Do not operate the Inverter with damaged or substandard wiring. 
CAUTION! To reduce risk of fire hazard, do not cover or obstruct the cooling fan. 
CAUTION! Do not operate the inverter if it has received a sharp blow, been dropped, or otherwise damaged in 
any way. If the inverter is damaged, called for an RMA (Return Material Authorization). 
WARNING: There are no user-replaceable parts inside of the inverter. Do not attempt to service the unit 
yourself. 
WARNING! It's very important for system safety and efficient operation to use appropriate external battery 
cable. To reduce risk of injury, external battery cables should be UL certified and rated for 105°C or higher. And 
do not use copper cables less than 6AWG or 10AWG*2. 

 

CAUTION! Do not disassemble the inverter. Contact with the qualified service center when service or repair is 
required. 
WARNING! Provide ventilation to outdoors from the battery compartment. The battery enclosure should be 

designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. 
CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, 

the batteries, or other equipments attached to this unit.   
CAUTION! For battery installation and maintenance, read the battery manufacturer's installation and 

maintenance instructions prior to operating. 

 

Personnel Precaution -   

CAUTION! Careful to reduce the risk or dropping a metal tool on the batteries. It could spark or short circuit the 
batteries and could cause an explosion. 

CAUTION! Remove personal metal items such as rings, bracelets, necklaces, and watches when working with 
batteries. Batteries can produce a short circuit current high enough to make metal melt, and could cause severe 
burns. 

CAUTION! Avoid touching eyes while working near batteries. 

Conventions used: 
WARNING! 
Warnings identify conditions or practices that could result in personal injury;   

CAUTION!    Caution identify conditions or practices that could result in damaged to the unit or other 

equipment connected. 

Содержание IVR-1200MPPT

Страница 1: ...USER MANUAL IVR 1200MPPT IVR 2400MPPT Solar Inverter...

Страница 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 5 6 Trouble Shooting 14 7 Specifications 15...

Страница 3: ...wire is not undersized Do not operate the Inverter with damaged or substandard wiring CAUTION To reduce risk of fire hazard do not cover or obstruct the cooling fan CAUTION Do not operate the inverter...

Страница 4: ...screws Connect to Utility and Charge Plug in the AC input cord to the wall outlet The unit will automatically charge the connected external battery even though the unit is off Connect to External Batt...

Страница 5: ...unit Step 5 Take the DC breaker on Connect to Solar Panel CAUTION Before connecting to PV modules please install separately a DC circuit breaker between inverter and PV modules WARNING All wiring must...

Страница 6: ...numbers Maximum PV module numbers in series Total PV module numbers Max Charging power of inverter Pmax of PV module 0 8 MPPT conversion rate Take IVR 1200MPPT inverter as an example to select proper...

Страница 7: ...Audible Alarms There are three indicators in the front panel of the unit LED Indicator Messages Green Solid On Output is available in bypass mode Flashing Output is powered by battery in inverter mode...

Страница 8: ...ne mode In AC mode it will present battery charging status Status Battery voltage LCD Display Constant Current mode Constant Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom...

Страница 9: ...VAC Narrow If selected acceptable AC input voltage range will be within 170 280VAC 02 Battery type AGM Default Flooded User defined 03 Max AC charging current 25A default 10A 04 Bulk charging C V volt...

Страница 10: ...and battery energy will provide power to the loads only when utility power is not available Solar first Solar energy provides power to the loads as first priority If solar energy is not sufficient to...

Страница 11: ...V default 11 8V 12 0V 12 3V 12 5V 12 8V Available options in IVR 2400MPPT model 22 0V 22 5V 23 0V default 23 5V 24 0V 24 5V 25 0V 25 5V 11 Setting voltage point back to battery mode when selecting SBU...

Страница 12: ...attery only when solar energy is not available Solar and utility Solar energy and utility will charge battery at the same time Only Solar Solar energy will be the only charger source no matter utility...

Страница 13: ...lay Input voltage Output voltage Default Display Screen Input Voltage 230V output voltage 230V Load percentage Load percent 70 Input frequency Input frequency 50Hz Load in VA When connected load is lo...

Страница 14: ...r can charge battery with AC bypass output Utility input bypass to output charger available LCD backlight is off Charging by utility and PV energy Charging by utility Charging by PV energy Line Mode T...

Страница 15: ...Icon on Fault Code Fault Event Icon on 00 Output short circuit 05 Fan locked 01 Over load time out 06 Over temperature 03 Output voltage too high 08 Over charge Warning Indicator Warning Code Warning...

Страница 16: ...ge output source priority to Utility first No LED display on the front panel when the utility power is normal No LED display Battery is not connected well Check the external battery cable and terminal...

Страница 17: ...ing Charge Voltage 13 7 VDC 0 5 VDC 27 4 VDC 1 VDC CV Charging Voltage Lead Acid Battery 14 3 VDC 0 5 VDC 28 6 VDC 1 VDC Lithium Battery 14 6 VDC 0 5 VDC 29 2 VDC 1 VDC Cut Off Voltage 10 5 VDC 0 5 VD...

Отзывы: