background image

 

LCD Display 

Display 

Function 

Input source information 

 

Indicates the AC input 

 

Indicates the PV input 

 

Indicates input voltage, input frequency, PV voltage, charging current, battery voltage,   

Configuration Program and Fault Information   

 

Indicates the setting programs. 

 

Indicates the warning and fault codes. 

Warning: 

  Flashing with warning code 

Fault: 

Lighting with fault code 

Output Information   

 

Indicates the output voltage, output frequency, load percent, load in VA, load in Watt, 

main board firmware version and SCC firmware version 

Battery Information   

 

Indicates the Battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode, 
charging status in line mode. 

In AC mode, it will present battery charging status. 

Status 

Battery voltage 

LCD Display 

Constant 
Current mode / 

Constant 
Voltage mode 

< 11Vdc/pcs 

4 bars will flash in turns. 

11Vdc ~ 11.5Vdc/pcs 

Bottom bar will be on and the other three 

bars will flash in turns. 

11.5Vdc ~ 12.5Vdc/pcs 

Bottom two bars will be on and the other 
two bars will flash in turns. 

> 12.5Vdc/pcs 

Bottom three bars will be on and the top 
bar will flash. 

Floating mode. Batteries are fully charged. 

4 bars will be on.   

 
In battery mode, it will present battery capacity.   

Battery Voltage 

LCD Display 

< 11Vdc/pcs 

 

11.0Vdc ~ 11.5Vdc/pcs 

 

11.5Vdc ~ 12.5Vdc/pcs 

 

> 12.5Vdc/pcs 

 

 

Load Information 

 

Indicates overload. 

 

Indicates the load level by 0-24%, 25-49%, 50-74%, and 75-100%.   

0%~24% 

25%~49% 

50%~74% 

75%~100% 

 

 

 

 

Mode operation information 

 

Indicates unit connects to the mains. 

 

Indicates unit connects to the PV panel 

Содержание IVR-1200MPPT

Страница 1: ...USER MANUAL IVR 1200MPPT IVR 2400MPPT Solar Inverter...

Страница 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 5 6 Trouble Shooting 14 7 Specifications 15...

Страница 3: ...wire is not undersized Do not operate the Inverter with damaged or substandard wiring CAUTION To reduce risk of fire hazard do not cover or obstruct the cooling fan CAUTION Do not operate the inverter...

Страница 4: ...screws Connect to Utility and Charge Plug in the AC input cord to the wall outlet The unit will automatically charge the connected external battery even though the unit is off Connect to External Batt...

Страница 5: ...unit Step 5 Take the DC breaker on Connect to Solar Panel CAUTION Before connecting to PV modules please install separately a DC circuit breaker between inverter and PV modules WARNING All wiring must...

Страница 6: ...numbers Maximum PV module numbers in series Total PV module numbers Max Charging power of inverter Pmax of PV module 0 8 MPPT conversion rate Take IVR 1200MPPT inverter as an example to select proper...

Страница 7: ...Audible Alarms There are three indicators in the front panel of the unit LED Indicator Messages Green Solid On Output is available in bypass mode Flashing Output is powered by battery in inverter mode...

Страница 8: ...ne mode In AC mode it will present battery charging status Status Battery voltage LCD Display Constant Current mode Constant Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom...

Страница 9: ...VAC Narrow If selected acceptable AC input voltage range will be within 170 280VAC 02 Battery type AGM Default Flooded User defined 03 Max AC charging current 25A default 10A 04 Bulk charging C V volt...

Страница 10: ...and battery energy will provide power to the loads only when utility power is not available Solar first Solar energy provides power to the loads as first priority If solar energy is not sufficient to...

Страница 11: ...V default 11 8V 12 0V 12 3V 12 5V 12 8V Available options in IVR 2400MPPT model 22 0V 22 5V 23 0V default 23 5V 24 0V 24 5V 25 0V 25 5V 11 Setting voltage point back to battery mode when selecting SBU...

Страница 12: ...attery only when solar energy is not available Solar and utility Solar energy and utility will charge battery at the same time Only Solar Solar energy will be the only charger source no matter utility...

Страница 13: ...lay Input voltage Output voltage Default Display Screen Input Voltage 230V output voltage 230V Load percentage Load percent 70 Input frequency Input frequency 50Hz Load in VA When connected load is lo...

Страница 14: ...r can charge battery with AC bypass output Utility input bypass to output charger available LCD backlight is off Charging by utility and PV energy Charging by utility Charging by PV energy Line Mode T...

Страница 15: ...Icon on Fault Code Fault Event Icon on 00 Output short circuit 05 Fan locked 01 Over load time out 06 Over temperature 03 Output voltage too high 08 Over charge Warning Indicator Warning Code Warning...

Страница 16: ...ge output source priority to Utility first No LED display on the front panel when the utility power is normal No LED display Battery is not connected well Check the external battery cable and terminal...

Страница 17: ...ing Charge Voltage 13 7 VDC 0 5 VDC 27 4 VDC 1 VDC CV Charging Voltage Lead Acid Battery 14 3 VDC 0 5 VDC 28 6 VDC 1 VDC Lithium Battery 14 6 VDC 0 5 VDC 29 2 VDC 1 VDC Cut Off Voltage 10 5 VDC 0 5 VD...