8
IVR-2400MPPT model default setting: 27.0V
If self-defined is selected in program 02, this program can be set up. Setting
range is from 13.0V to 14.6V for
IVR-1200MPPT
model and increment of each
click is 0.1V. Setting range is from 26.0V to 29.2V for
IVR-2400MPPT
model and
increment of each click is 0.2V.
06
Low DC cut-off
voltage
IVR-1200MPPT
default setting:
10.5V
IVR-2400MPPT
default setting:
21V
Setting range is from 9.9V to 12.0V for
IVR-1200MPPT
model and increment of
each click is 0.1V Setting range is from 19.8V to 24.0V for
IVR-2400MPPT
model
and increment of each click is 0.2V. Low DC cut-off voltage will be fixed to
setting value no matter what percentage of load is connected.
07
Output source
priority:
To configure load
power source
priority
Utility first (default)
Utility will provide power to the loads as first priority.
Solar and battery energy will provide power to the
loads only when utility power is not available.
Solar first
Solar energy provides power to the loads as first
priority.
If solar energy is not sufficient to power all connected
loads, battery energy will supply power the loads at
the same time.
Utility provides power to the loads only when any one
condition happens:
- Solar energy is not available
- Battery voltage drops to low-level warning voltage or
the setting point in program 10.
SBU priority
Solar energy provides power to the loads as first
priority.
If solar energy is not sufficient to power all connected
loads, battery energy will supply power to the loads at
the same time.
Utility provides power to the loads only when battery
voltage drops to either low-level warning voltage or
the setting point in program 10.
08
Maximum charging
current: To
configure total
charging current for
solar and utility
chargers.
(Max. charging
current = utility
charging c
solar charging
current)
10A
20A
30A
40A
55A (default)
09
Output frequency
50Hz (default)
60Hz