Page 33
MMAE16 - Servce & Parts Manual
Aprl 2022
Secton 11 - Control System
Saving New Values
New values must be saved immediately after adjustment.
To save new values, press and hold the Horn button for 3 seconds.
To operate the machine with new values, press the Emergency Stop
button, then rotate it to return to the ON position.
ART_5135
High Drive Speed
This parameter controls high speed drive when the platform is in the
stowed position.
Press the Drive Mode Select button. The button will light up,
indicating this mode is active, and the LED Indicator will show the
present setting.
Adjust the speed using the steer left and steer right buttons on top
of the Control Handle.
High Drive Speed may be changed from 00 to 9°9. Factory setting
is 9°9.
Save the new setting (See top of page for “Saving New Values“).
1.
2.
3.
4.
ART_5130
Low Speed Drive
This parameter controls low speed drive when the platform is in the
stowed position and Low Speed is selected (turtle icon).
Press the Drive Mode Select button. The button will light up,
indicating this mode is active.
Press and hold the Low Speed Mode Select button (turtle icon).
The button will light up, and the LED Indicator will show the present
setting.
Adjust the speed using the steer left and steer right buttons on top
of the Control Handle.
Low Drive Speed can be set from 00 to 9°9, but must not be set
higher than 50. Factory setting is 50.
DO NOT ADJUST THE SETTING HIGHER THAN
50�����
Save the new setting (See top of page for “Saving New Values“).
1.
2.
3.
4.
5.
ART_5131