Page 32
MMAE16 - Servce & Parts Manual
Aprl 2022
Secton 11 - Control System
Parameter Adjustment
PARAMETERS SHOULD BE ADJUSTED ONLY IF THE FUNCTION IS
OPERATING OUTSIDE OF MACHINE SPECIFICATIONS, OR IF WRITTEN
APPROVAL IS OBTAINED FROM MEC PRIOR TO MAKING THE CHANGE�����
The following adjustments are made at the Platform Controls station
using the LED Indicator to display the current settings. Follow the
instructions to reach the desired setting.
Change the setting by using the Steer Buttons on top of the control
handle. The right button increases the setting. The left button decreases
the setting.
Number represent a percentage. 99 means 99%. 9°9 (dot between the
digits) means 100%.
ART_5127
LED Indicator
Speed Adjustment State
Set the key switch at the Base Controls to PLATFORM. Twist the
Base Emergency Stop Switch out to the ON position.
Push the Platform Controls Emergency Stop Button in to the OFF
Position.
Press and hold the HORN and LIFT buttons, then twist the
Platform Emergency Stop Switch to the ON position.
1.
2.
3.
ART_5128
“PS” and the current Lift Speed setting will alternate on the LED
Indicator.
Refer to the following pages for individual operating adjustments.
4.
ART_5129