Page 27
Mcro 26 - Operator’s Manual
March 2019
Secton 8 - Mantenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualified service technician.
ART_5181
2632
SE
3346
SE
4046
SE
4555
SE
1930
SE
Hydraulic
Pump & Motor
Hydraulic
Reservoir
Hydraulic
Filter
Hydraulic
Pump & Motor
Hydraulic
Reservoir
Hydraulic
Filter
FULL -- 16L
Controls
Tray
Controls
Tray
ADD -- 13L
Breather Cap
FULL
ADD
No�����
Item
Specification
Frequency
1
Hydraulic Reservoir
Mobile Fluid DTE 10, DTE 13 M, or AW32
Do not substitute other fluids as pump
damage may result�����
Check as shown above with platform in
the stowed position. Fill as needed.
Routine Maintenance
Check hydraulic oil level every week
Scheduled Maintenance
Change yearly or every 600 hours,
whichever occurs first.
2
Hydraulic Cap
Breather Filter and
Hydraulic Filter
Breather Filter (located inside Filler Cap)
Hydraulic Filter Canister
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours,
whichever occurs first
Severe Conditions -- Very dusty,
exceptionally hot or exceptionally cold
conditions
Change every three months or 150 hours,
whichever occurs first.